Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.838 kW
07/17/2026 14:52 (2242 days) Production Consumption NET Usage
Now 4.231 kW 2.393 kW -1.838 kW
Today 23.949 kWh (1.609 kW) 12.520 kWh (0.841 kW) -11.429 kWh (-0.768 kW)
  - This Week 169.976 kWh (30.246 kWh/day) 181.461 kWh (32.290 kWh/day) 11.485 kWh (2.044 kWh/day)
  - This Month 440.530 kWh (26.505 kWh/day) 579.424 kWh (34.862 kWh/day) 138.894 kWh (8.357 kWh/day)
  - This Year 4.050 MWh (20.496 kWh/day) 3.866 MWh (19.564 kWh/day) -0.184 MWh (-0.932 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 204.359 kWh (29.194 kWh/day) 231.256 kWh (33.037 kWh/day) 26.897 kWh (3.842 kWh/day)
Last 30 Days (06/17/2026) 746.962 kWh (24.899 kWh/day) 872.251 kWh (29.075 kWh/day) 125.289 kWh (4.176 kWh/day)
Last One Year 6.738 MWh (18.459 kWh/day) 7.647 MWh (20.950 kWh/day) 0.909 MWh (2.491 kWh/day)
Lifetime Since PTO 39.616 MWh (17.665 kW/day) 43.377 MWh (19.342 kW/day) 3.761 MWh (1.677 kW/day)
Lifetime Since Install 39.650 MWh 43.957 MWh 4.307 MWh
Voltage/Current 248.8 V / 17.0 A 248.8 V / 9.6 A 248.8 V / -7.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/05/2020 23:20 (9.9 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.577 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.222 1.156 1.171 5.371 0.000 kW
1.153 kWh
0.000 kW
6.917 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.223 1.142 1.162 5.187
03 - 202224****** IQ7+M [5] VCOP 0.000 0.226 1.156 1.170 5.280
04 - 202232****** IQ7+ [5] VCOP 0.000 0.225 1.145 1.162 5.231
05 - 202244****** IQ7+M [5] VCOP 0.000 0.225 1.169 1.181 5.313
06 - 202245****** IQ7+M [5] VCOP 0.000 0.222 1.150 1.178 5.408
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.273 1.389 1.411 6.167 0.000 kW
1.415 kWh
0.000 kW
7.075 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.284 1.247 5.698
09 - 202217****** IQ7+ [5] VCOP 0.000 0.276 1.489 1.541 6.549
10 - 202244****** IQ7+M [5] VCOP 0.000 0.277 1.490 1.539 6.550
11 - 202224****** IQ7+M [5] VCOP 0.000 0.273 1.422 1.473 6.303
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.128 0.605 0.627 3.240 0.000 kW
0.646 kWh
0.000 kW
2.585 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.127 0.665 0.680 3.432
14 - 202216****** IQ7+ [5] VCOP 0.000 0.128 0.664 0.681 3.478
15 - 202245****** IQ7+M [5] VCOP 0.000 0.126 0.650 0.668 3.406
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.