Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.051 kW
04/10/2026 06:49 (2144 days) Production Consumption NET Usage
Now 0.360 kW 0.411 kW 0.051 kW
Today 2.180 kWh (0.318 kW) 36.856 kWh (5.375 kW) 34.676 kWh (5.057 kW)
  - This Week 152.056 kWh (28.774 kWh/day) 106.845 kWh (20.219 kWh/day) -45.211 kWh (-8.556 kWh/day)
  - This Month 204.661 kWh (22.043 kWh/day) 167.904 kWh (18.084 kWh/day) -36.757 kWh (-3.959 kWh/day)
  - This Year 1.434 MWh (14.444 kWh/day) 1.733 MWh (17.457 kWh/day) 0.299 MWh (3.013 kWh/day)
Yesterday 38.872 kWh (1.622 kW) 13.357 kWh (0.557 kW) -25.515 kWh (-1.065 kW)
Last 7 Days 187.862 kWh (26.837 kWh/day) 133.711 kWh (19.102 kWh/day) -54.151 kWh (-7.736 kWh/day)
Last 30 Days (03/11/2026) 646.528 kWh (21.551 kWh/day) 481.756 kWh (16.059 kWh/day) -164.772 kWh (-5.492 kWh/day)
Last One Year 6.179 MWh (16.928 kWh/day) 7.865 MWh (21.548 kWh/day) 1.687 MWh (4.621 kWh/day)
Lifetime Since PTO 37.000 MWh (17.255 kW/day) 41.244 MWh (19.234 kW/day) 4.244 MWh (1.979 kW/day)
Lifetime Since Install 37.034 MWh 41.824 MWh 4.790 MWh
Voltage/Current 249.9 V / 1.4 A 249.9 V / 1.6 A 249.9 V / 0.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/03/2020 21:18 (13.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.219 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.047 1.388 12.029 0.000 kW
1.979 kWh
0.000 kW
11.874 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.973 1.375 11.656
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.996 1.397 11.782
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.022 1.391 11.880
05 - 202244****** IQ7+M [5] VC-- 0.000 0.296 1.857 1.380 11.020
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.979 1.378 11.705
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.905 1.376 10.897 0.000 kW
1.902 kWh
0.000 kW
9.508 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.895 1.420 11.307
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.899 1.389 11.032
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.909 1.430 11.399
11 - 202224****** IQ7+M [5] VC-- 0.000 0.297 1.900 1.426 11.411
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.258 1.990 1.126 11.437 0.000 kW
1.959 kWh
0.000 kW
7.837 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.257 1.917 1.082 10.992
14 - 202216****** IQ7+ [5] VCOP 0.000 0.257 1.981 1.143 11.452
15 - 202245****** IQ7+M [5] VCOP 0.000 0.254 1.950 1.123 11.264
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.