Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 5.947 kW
04/10/2026 04:52 (2144 days) Production Consumption NET Usage
Now 0.317 kW 6.264 kW 5.947 kW
Today 1.552 kWh (0.317 kW) 30.562 kWh (6.236 kW) 29.010 kWh (5.919 kW)
  - This Week 151.428 kWh (29.104 kWh/day) 100.551 kWh (19.326 kWh/day) -50.877 kWh (-9.778 kWh/day)
  - This Month 204.033 kWh (22.170 kWh/day) 161.610 kWh (17.561 kWh/day) -42.423 kWh (-4.610 kWh/day)
  - This Year 1.433 MWh (14.450 kWh/day) 1.727 MWh (17.408 kWh/day) 0.294 MWh (2.959 kWh/day)
Yesterday 38.872 kWh (1.622 kW) 13.357 kWh (0.557 kW) -25.515 kWh (-1.065 kW)
Last 7 Days 187.234 kWh (26.748 kWh/day) 128.246 kWh (18.321 kWh/day) -58.988 kWh (-8.427 kWh/day)
Last 30 Days (03/11/2026) 645.900 kWh (21.530 kWh/day) 476.571 kWh (15.886 kWh/day) -169.329 kWh (-5.644 kWh/day)
Last One Year 6.178 MWh (16.926 kWh/day) 7.860 MWh (21.534 kWh/day) 1.682 MWh (4.608 kWh/day)
Lifetime Since PTO 36.999 MWh (17.255 kW/day) 41.238 MWh (19.232 kW/day) 4.239 MWh (1.977 kW/day)
Lifetime Since Install 37.033 MWh 41.818 MWh 4.785 MWh
Voltage/Current 249.1 V / 1.3 A 249.0 V / 25.2 A 249.0 V / 23.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/18/2020 23:11 (12.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.632 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.284 1.510 1.020 9.437 0.000 kW
1.501 kWh
0.000 kW
9.008 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.281 1.493 1.006 9.348
03 - 202224****** IQ7+M [0] ---- 0.000 0.288 1.517 1.021 9.516
04 - 202232****** IQ7+ [0] ---- 0.000 0.286 1.507 1.009 9.436
05 - 202244****** IQ7+M [0] ---- 0.000 0.284 1.491 0.987 9.173
06 - 202245****** IQ7+M [0] ---- 0.000 0.279 1.490 1.000 9.210
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.579 0.956 9.543 0.000 kW
1.584 kWh
0.000 kW
7.918 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.555 0.931 9.272
09 - 202217****** IQ7+ [0] ---- 0.000 0.295 1.586 0.967 9.568
10 - 202244****** IQ7+M [0] ---- 0.000 0.298 1.603 0.974 9.740
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.595 0.963 9.650
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.234 1.181 0.950 7.962 0.000 kW
1.176 kWh
0.000 kW
4.706 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.234 1.162 0.951 7.862
14 - 202216****** IQ7+ [0] ---- 0.000 0.236 1.191 0.961 8.028
15 - 202245****** IQ7+M [0] ---- 0.000 0.234 1.172 0.948 7.903
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.62 V Current/Power 180.00 A (10.372 kW)
Remain Capacity/Energy 576.9 Ah (29.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 97.6 % State Of Health 98.5 %
Run Time 4m to full Report Date 2020-09-18 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack