Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.049 kW
02/08/2026 05:15 (2083 days) Production Consumption NET Usage
Now 0.317 kW 0.268 kW -0.049 kW
Today 1.666 kWh (0.317 kW) 2.489 kWh (0.473 kW) 0.823 kWh (0.156 kW)
  - This Week 1.666 kWh (7.603 kWh/day) 2.489 kWh (11.358 kWh/day) 0.823 kWh (3.756 kWh/day)
  - This Month 113.498 kWh (15.720 kWh/day) 143.748 kWh (19.910 kWh/day) 30.250 kWh (4.190 kWh/day)
  - This Year 0.359 MWh (9.391 kWh/day) 0.727 MWh (19.020 kWh/day) 0.368 MWh (9.629 kWh/day)
Yesterday 17.851 kWh (0.744 kW) 11.028 kWh (0.460 kW) -6.823 kWh (-0.284 kW)
Last 7 Days 111.813 kWh (16.493 kWh/day) 141.359 kWh (20.852 kWh/day) 29.546 kWh (4.358 kWh/day)
Last 30 Days 291.104 kWh (9.775 kWh/day) 554.843 kWh (18.632 kWh/day) 263.739 kWh (8.856 kWh/day)
Last One Year 6.117 MWh (16.768 kWh/day) 7.571 MWh (20.755 kWh/day) 1.454 MWh (3.987 kWh/day)
Lifetime Since PTO 35.925 MWh (17.244 kW/day) 40.238 MWh (19.315 kW/day) 4.314 MWh (2.071 kW/day)
Lifetime Since Install 35.959 MWh 40.818 MWh 4.860 MWh
Voltage/Current 250.4 V / 1.3 A 250.5 V / 1.1 A 250.5 V / -0.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/02/2020 23:15 (13.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 19.826 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.388 1.759 12.813 0.000 kW
1.385 kWh
0.000 kW
8.310 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.375 1.690 12.377
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.397 1.715 12.498
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.391 1.744 12.615
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.380 1.556 11.639
06 - 202245****** IQ7+M [0] ---- 0.000 0.295 1.378 1.701 12.435
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.298 1.376 1.576 11.497 0.000 kW
1.408 kWh
0.000 kW
7.042 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.420 1.642 11.924
09 - 202217****** IQ7+ [0] ---- 0.000 0.298 1.389 1.596 11.653
10 - 202244****** IQ7+M [0] ---- 0.000 0.298 1.430 1.657 12.022
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.426 1.658 12.035
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.280 1.126 1.763 12.331 0.000 kW
1.119 kWh
0.000 kW
4.474 kWh
13 - 202223****** IQ7+ [0] V--- 0.000 0.285 1.082 1.682 11.852
14 - 202216****** IQ7+ [0] ---- 0.000 0.284 1.143 1.772 12.325
15 - 202245****** IQ7+M [0] ---- 0.000 0.277 1.123 1.746 12.118
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.61 V Current/Power 179.79 A (10.357 kW)
Remain Capacity/Energy 576.0 Ah (29.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.8 % State Of Health 96.2 %
Run Time - to full Report Date 2020-08-02 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.