Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 6.036 kW
04/10/2026 05:09 (2144 days) Production Consumption NET Usage
Now 0.316 kW 6.352 kW 6.036 kW
Today 1.642 kWh (0.317 kW) 32.377 kWh (6.242 kW) 30.735 kWh (5.926 kW)
  - This Week 151.518 kWh (29.055 kWh/day) 102.366 kWh (19.630 kWh/day) -49.152 kWh (-9.425 kWh/day)
  - This Month 204.123 kWh (22.151 kWh/day) 163.425 kWh (17.735 kWh/day) -40.698 kWh (-4.417 kWh/day)
  - This Year 1.434 MWh (14.449 kWh/day) 1.729 MWh (17.424 kWh/day) 0.295 MWh (2.976 kWh/day)
Yesterday 38.872 kWh (1.622 kW) 13.357 kWh (0.557 kW) -25.515 kWh (-1.065 kW)
Last 7 Days 187.324 kWh (26.761 kWh/day) 129.950 kWh (18.564 kWh/day) -57.374 kWh (-8.196 kWh/day)
Last 30 Days (03/11/2026) 645.990 kWh (21.533 kWh/day) 478.262 kWh (15.942 kWh/day) -167.728 kWh (-5.591 kWh/day)
Last One Year 6.178 MWh (16.926 kWh/day) 7.862 MWh (21.539 kWh/day) 1.684 MWh (4.612 kWh/day)
Lifetime Since PTO 36.999 MWh (17.255 kW/day) 41.240 MWh (19.233 kW/day) 4.240 MWh (1.978 kW/day)
Lifetime Since Install 37.033 MWh 41.820 MWh 4.786 MWh
Voltage/Current 248.7 V / 1.3 A 248.6 V / 25.6 A 248.6 V / 24.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/12/2020 22:20 (10.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.045 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.045 0.143 0.570 8.437 0.000 kW
0.141 kWh
0.000 kW
0.846 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.044 0.140 0.561 8.323
03 - 202224****** IQ7+M [0] ---- 0.000 0.043 0.144 0.572 8.428
04 - 202232****** IQ7+ [0] ---- 0.000 0.044 0.141 0.563 8.350
05 - 202244****** IQ7+M [0] ---- 0.000 0.043 0.138 0.547 8.224
06 - 202245****** IQ7+M [0] ---- 0.000 0.045 0.140 0.554 8.191
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.040 0.127 0.518 8.621 0.000 kW
0.127 kWh
0.000 kW
0.635 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.040 0.127 0.514 7.943
09 - 202217****** IQ7+ [0] ---- 0.000 0.039 0.127 0.530 8.814
10 - 202244****** IQ7+M [0] ---- 0.000 0.040 0.128 0.534 8.959
11 - 202224****** IQ7+M [0] ---- 0.000 0.040 0.127 0.523 8.843
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.041 0.139 0.553 6.290 0.000 kW
0.141 kWh
0.000 kW
0.563 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.041 0.141 0.557 6.268
14 - 202216****** IQ7+ [0] ---- 0.000 0.042 0.143 0.564 6.352
15 - 202245****** IQ7+M [0] ---- 0.000 0.042 0.141 0.556 6.243
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.03 V Current/Power 175.09 A (9.810 kW)
Remain Capacity/Energy 559.2 Ah (28.6 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 94.6 % State Of Health 98.5 %
Run Time 10m to full Report Date 2020-10-12 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.