Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.010 kW
02/08/2026 05:17 (2083 days) Production Consumption NET Usage
Now 0.317 kW 0.307 kW -0.010 kW
Today 1.678 kWh (0.317 kW) 2.501 kWh (0.472 kW) 0.823 kWh (0.155 kW)
  - This Week 1.678 kWh (7.601 kWh/day) 2.501 kWh (11.329 kWh/day) 0.823 kWh (3.728 kWh/day)
  - This Month 113.510 kWh (15.718 kWh/day) 143.760 kWh (19.907 kWh/day) 30.250 kWh (4.189 kWh/day)
  - This Year 0.359 MWh (9.391 kWh/day) 0.727 MWh (19.020 kWh/day) 0.368 MWh (9.629 kWh/day)
Yesterday 17.851 kWh (0.744 kW) 11.028 kWh (0.460 kW) -6.823 kWh (-0.284 kW)
Last 7 Days 111.825 kWh (16.495 kWh/day) 141.371 kWh (20.854 kWh/day) 29.546 kWh (4.358 kWh/day)
Last 30 Days 291.104 kWh (9.775 kWh/day) 554.843 kWh (18.632 kWh/day) 263.739 kWh (8.856 kWh/day)
Last One Year 6.117 MWh (16.768 kWh/day) 7.571 MWh (20.755 kWh/day) 1.454 MWh (3.987 kWh/day)
Lifetime Since PTO 35.925 MWh (17.244 kW/day) 40.238 MWh (19.315 kW/day) 4.314 MWh (2.071 kW/day)
Lifetime Since Install 35.959 MWh 40.818 MWh 4.860 MWh
Voltage/Current 250.8 V / 1.3 A 250.8 V / 1.2 A 250.8 V / -0.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/12/2020 23:03 (13.4 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.257 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.547 1.767 11.257 0.000 kW
1.499 kWh
0.000 kW
8.991 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.498 1.739 11.000
03 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.531 1.772 11.194
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.543 1.769 11.216
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.390 1.640 10.442
06 - 202245****** IQ7+M [0] ---- 0.000 0.295 1.483 1.733 10.952
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.299 1.364 1.675 10.488 0.000 kW
1.390 kWh
0.000 kW
6.949 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.299 1.384 1.722 10.643
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.369 1.686 10.555
10 - 202244****** IQ7+M [0] ---- 0.000 0.298 1.417 1.744 10.782
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.416 1.747 10.780
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.264 1.587 1.579 10.440 0.000 kW
1.579 kWh
0.000 kW
6.317 kWh
13 - 202223****** IQ7+ [0] V--- 0.000 0.265 1.575 1.507 10.126
14 - 202216****** IQ7+ [0] ---- 0.000 0.268 1.590 1.591 10.497
15 - 202245****** IQ7+M [0] ---- 0.000 0.261 1.565 1.568 10.343
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.