Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 6.006 kW
04/10/2026 01:05 (2144 days) Production Consumption NET Usage
Now 0.317 kW 6.323 kW 6.006 kW
Today 0.358 kWh (0.317 kW) 6.148 kWh (5.438 kW) 5.790 kWh (5.121 kW)
  - This Week 150.234 kWh (29.774 kWh/day) 76.137 kWh (15.089 kWh/day) -74.097 kWh (-14.685 kWh/day)
  - This Month 202.839 kWh (22.423 kWh/day) 137.196 kWh (15.167 kWh/day) -65.643 kWh (-7.257 kWh/day)
  - This Year 1.432 MWh (14.460 kWh/day) 1.703 MWh (17.189 kWh/day) 0.270 MWh (2.729 kWh/day)
Yesterday 38.872 kWh (1.622 kW) 13.357 kWh (0.557 kW) -25.515 kWh (-1.065 kW)
Last 7 Days 186.040 kWh (26.577 kWh/day) 105.178 kWh (15.025 kWh/day) -80.862 kWh (-11.552 kWh/day)
Last 30 Days (03/11/2026) 644.706 kWh (21.490 kWh/day) 453.429 kWh (15.114 kWh/day) -191.277 kWh (-6.376 kWh/day)
Last One Year 6.177 MWh (16.923 kWh/day) 7.837 MWh (21.471 kWh/day) 1.660 MWh (4.548 kWh/day)
Lifetime Since PTO 36.998 MWh (17.256 kW/day) 41.213 MWh (19.222 kW/day) 4.215 MWh (1.966 kW/day)
Lifetime Since Install 37.032 MWh 41.793 MWh 4.761 MWh
Voltage/Current 248.8 V / 1.3 A 248.7 V / 25.4 A 248.7 V / 24.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/08/2020 21:56 (9.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.545 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.212 1.093 1.103 6.843 0.000 kW
1.094 kWh
0.000 kW
6.562 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.207 1.081 1.084 6.694
03 - 202224****** IQ7+M [0] ---- 0.000 0.212 1.100 1.102 6.768
04 - 202232****** IQ7+ [0] ---- 0.000 0.211 1.087 1.091 6.714
05 - 202244****** IQ7+M [0] ---- 0.000 0.211 1.103 1.108 6.838
06 - 202245****** IQ7+M [0] ---- 0.000 0.208 1.100 1.104 6.864
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.258 1.268 1.289 8.136 0.000 kW
1.316 kWh
0.000 kW
6.579 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.256 1.131 1.136 7.444
09 - 202217****** IQ7+ [0] ---- 0.000 0.256 1.442 1.461 8.764
10 - 202244****** IQ7+M [0] ---- 0.000 0.257 1.419 1.434 8.730
11 - 202224****** IQ7+M [0] ---- 0.000 0.255 1.320 1.351 8.393
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.119 0.562 0.573 3.775 0.000 kW
0.601 kWh
0.000 kW
2.404 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.119 0.620 0.628 4.083
14 - 202216****** IQ7+ [0] ---- 0.000 0.119 0.619 0.627 4.092
15 - 202245****** IQ7+M [0] ---- 0.000 0.115 0.603 0.611 4.010
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.03 V Current/Power 178.16 A (10.161 kW)
Remain Capacity/Energy 589.8 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Run Time - to full Report Date 2020-11-08 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.