Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.416 kW
03/17/2026 13:52 (2120 days) Production Consumption NET Usage
Now 0.898 kW 0.482 kW -0.416 kW
Today 16.365 kWh (1.179 kW) 6.129 kWh (0.442 kW) -10.236 kWh (-0.738 kW)
  - This Week 33.469 kWh (12.981 kWh/day) 33.239 kWh (12.892 kWh/day) -0.230 kWh (-0.089 kWh/day)
  - This Month 268.190 kWh (16.177 kWh/day) 237.266 kWh (14.312 kWh/day) -30.924 kWh (-1.865 kWh/day)
  - This Year 0.902 MWh (11.936 kWh/day) 1.337 MWh (17.691 kWh/day) 0.435 MWh (5.755 kWh/day)
Yesterday 5.215 kWh (0.217 kW) 14.236 kWh (0.593 kW) 9.021 kWh (0.376 kW)
Last 7 Days 125.292 kWh (17.899 kWh/day) 95.396 kWh (13.628 kWh/day) -29.896 kWh (-4.271 kWh/day)
Last 30 Days (02/15/2026) 390.904 kWh (13.030 kWh/day) 452.736 kWh (15.091 kWh/day) 61.832 kWh (2.061 kWh/day)
Last One Year 6.053 MWh (16.585 kWh/day) 7.841 MWh (21.481 kWh/day) 1.787 MWh (4.897 kWh/day)
Lifetime Since PTO 36.468 MWh (17.197 kW/day) 40.848 MWh (19.263 kW/day) 4.380 MWh (2.066 kW/day)
Lifetime Since Install 36.502 MWh 41.428 MWh 4.926 MWh
Voltage/Current 248.6 V / 3.6 A 248.6 V / 1.9 A 248.6 V / -1.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:5, pcu_level:1]
Recent Report Data/Time 09/05/2025 23:55 (23.9 hours) Number of Devices 17 set
Current Power 0.230 kW (0.014 kW/panel) Today Energy 27.931 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.279 1.567 1.603 12.315 0.000 kW
1.540 kWh
0.000 kW
9.237 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.268 1.500 1.540 11.791
03 - 202224****** IQ7+M [5] VCOP 0.000 0.278 1.560 1.606 12.286
04 - 202232****** IQ7+ [5] VCOP 0.000 0.281 1.581 1.641 12.488
05 - 202244****** IQ7+M [5] VCOP 0.000 0.268 1.495 1.474 11.268
06 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.533 1.508 11.662
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.287 1.556 1.482 11.749 0.000 kW
1.579 kWh
0.000 kW
7.896 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.289 1.583 1.585 12.174
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 1.580 1.587 12.029
10 - 202244****** IQ7+M [5] VCOP 0.000 0.291 1.579 1.582 12.262
11 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.598 1.601 12.477
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.226 1.270 1.421 10.504 0.000 kW
1.314 kWh
0.000 kW
5.257 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.231 1.309 1.446 10.607
14 - 202216****** IQ7+ [5] VCOP 0.000 0.233 1.331 1.486 10.967
15 - 202245****** IQ7+M [5] VCOP 0.000 0.233 1.346 1.491 10.988
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.115 kW
2.770 kWh
0.230 kW
5.541 kWh
17 - 122214****** IQ7PD [5] VCOP 0.230 0.230 5.541 5.476 38.448
Panel Layout Each Group Production

Charger History
Voltage PV 1.64 V Voltage Charge 52.74 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 31.5 °C / 28.7 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-09-05 23:57
voltage in/out power and energy internal/external temperature

Battery History
Voltage 53.02 V Current/Power -6.38 A (-0.338 kW)
Remain Capacity/Energy 363.9 Ah (18.6 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 61.4 % State Of Health 98.9 %
Run Time 2d 9h 2m to empty Report Date 2025-09-05 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.