Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.212 kW
07/17/2026 10:49 (2242 days) Production Consumption NET Usage
Now 2.566 kW 0.354 kW -2.212 kW
Today 8.652 kWh (0.798 kW) 5.849 kWh (0.540 kW) -2.803 kWh (-0.259 kW)
  - This Week 154.679 kWh (28.375 kWh/day) 174.790 kWh (32.064 kWh/day) 20.111 kWh (3.689 kWh/day)
  - This Month 425.233 kWh (25.847 kWh/day) 572.753 kWh (34.814 kWh/day) 147.520 kWh (8.967 kWh/day)
  - This Year 4.035 MWh (20.436 kWh/day) 3.860 MWh (19.547 kWh/day) -0.176 MWh (-0.889 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 199.159 kWh (28.451 kWh/day) 235.864 kWh (33.695 kWh/day) 36.705 kWh (5.244 kWh/day)
Last 30 Days (06/17/2026) 743.116 kWh (24.771 kWh/day) 866.815 kWh (28.894 kWh/day) 123.699 kWh (4.123 kWh/day)
Last One Year 6.733 MWh (18.447 kWh/day) 7.645 MWh (20.944 kWh/day) 0.911 MWh (2.497 kWh/day)
Lifetime Since PTO 39.601 MWh (17.660 kW/day) 43.370 MWh (19.341 kW/day) 3.770 MWh (1.681 kW/day)
Lifetime Since Install 39.635 MWh 43.950 MWh 4.316 MWh
Voltage/Current 249.0 V / 10.3 A 249.0 V / 1.4 A 249.0 V / -8.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/09/2021 22:15 (12.9 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 18.919 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.294 1.303 2.085 13.373 0.000 kW
1.275 kWh
0.000 kW
7.649 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.270 2.053 13.120
03 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.310 2.112 13.442
04 - 202232****** IQ7+ [5] VCOP 0.000 0.293 1.312 2.134 13.442
05 - 202244****** IQ7+M [5] VCOP 0.000 0.287 1.216 1.967 12.690
06 - 202245****** IQ7+M [5] VCOP 0.000 0.284 1.239 1.962 12.708
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.292 1.216 2.112 13.417 0.000 kW
1.210 kWh
0.000 kW
6.049 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.161 2.069 13.237
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 1.224 2.078 13.232
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.233 2.167 13.750
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.215 2.177 13.761
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.246 1.303 1.749 11.143 0.000 kW
1.305 kWh
0.000 kW
5.221 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.247 1.303 1.670 10.722
14 - 202216****** IQ7+ [5] VCOP 0.000 0.249 1.314 1.755 11.156
15 - 202245****** IQ7+M [5] VCOP 0.000 0.244 1.301 1.729 10.967
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.25 V Current/Power -1.80 A (-95 W)
Remain Capacity/Energy 528.9 Ah (27.1 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 88.2 % State Of Health 100.0 %
Run Time 12d 5h 50m to empty Report Date 2021-04-09 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack