Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.083 kW
11/03/2025 08:09 (1986 days) Production Consumption NET Usage
Now 0.713 kW 0.796 kW 0.083 kW
Today 0.278 kWh (0.034 kW) 2.059 kWh (0.252 kW) 1.781 kWh (0.218 kW)
  - This Week 17.449 kWh (13.021 kWh/day) 28.376 kWh (21.175 kWh/day) 10.927 kWh (8.154 kWh/day)
  - This Month 34.387 kWh (14.693 kWh/day) 44.564 kWh (19.041 kWh/day) 10.177 kWh (4.348 kWh/day)
  - This Year 5.612 MWh (18.321 kWh/day) 6.377 MWh (20.817 kWh/day) 0.765 MWh (2.496 kWh/day)
Yesterday 17.171 kWh (0.716 kW) 26.317 kWh (1.097 kW) 9.146 kWh (0.381 kW)
Last 7 Days 86.148 kWh (12.307 kWh/day) 98.955 kWh (14.137 kWh/day) 12.807 kWh (1.830 kWh/day)
Last 30 Days 441.432 kWh (14.715 kWh/day) 484.805 kWh (16.161 kWh/day) 43.373 kWh (1.446 kWh/day)
Last One Year 6.208 MWh (17.008 kWh/day) 7.431 MWh (20.358 kWh/day) 1.223 MWh (3.350 kWh/day)
Lifetime Since PTO 35.063 MWh (17.652 kW/day) 38.330 MWh (19.296 kW/day) 3.266 MWh (1.644 kW/day)
Lifetime Since Install 35.097 MWh 38.910 MWh 3.813 MWh
Voltage/Current 248.9 V / 2.9 A 249.0 V / 3.2 A 248.9 V / 0.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/28/2020 23:26 (14.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.666 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.798 2.152 12.128 0.000 kW
1.727 kWh
0.000 kW
10.361 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.729 2.070 11.762
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.742 2.082 11.844
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.764 2.110 11.921
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.589 1.921 11.039
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.739 2.083 11.820
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.571 1.916 10.930 0.000 kW
1.605 kWh
0.000 kW
8.024 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.611 1.992 11.185
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.585 1.940 11.050
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.628 2.006 11.285
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.629 2.011 11.257
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.278 1.846 2.077 11.804 0.000 kW
1.820 kWh
0.000 kW
7.281 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.277 1.793 1.990 11.474
14 - 202216****** IQ7+ [5] VCOP 0.000 0.276 1.838 2.066 11.828
15 - 202245****** IQ7+M [5] VCOP 0.000 0.272 1.804 2.029 11.649
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.20 V Current/Power 166.16 A (8.840 kW)
Remain Capacity/Energy 514.8 Ah (26.4 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 89.2 % State Of Health 96.2 %
Run Time 22m to full Report Date 2020-07-28 23:24
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.20 V Cell (MIN/MAX) 3.319 V / 3.329 V (0.010 V)
Current/Power -0.53 A (-28 W) Runtime 13d 9h 20m to empty
Remain Capacity/Energy 171.6 Ah (8.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 89.2 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-07-28 23:24
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.319 V 3.321 V 3.321 V 3.322 V 3.323 V 3.323 V 3.324 V 3.324 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.326 V 3.326 V 3.326 V 3.328 V 3.329 V 3.328 V 3.329 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -