Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 3.588 kW
04/09/2026 22:40 (2143 days) Production Consumption NET Usage
Now 0.316 kW 3.904 kW 3.588 kW
Today 38.461 kWh (1.696 kW) 6.917 kWh (0.305 kW) -31.544 kWh (-1.391 kW)
  - This Week 149.465 kWh (30.227 kWh/day) 63.549 kWh (12.852 kWh/day) -85.916 kWh (-17.375 kWh/day)
  - This Month 202.070 kWh (22.591 kWh/day) 124.608 kWh (13.931 kWh/day) -77.462 kWh (-8.660 kWh/day)
  - This Year 1.431 MWh (14.467 kWh/day) 1.690 MWh (17.080 kWh/day) 0.258 MWh (2.612 kWh/day)
Yesterday 39.481 kWh (1.645 kW) 21.070 kWh (0.878 kW) -18.411 kWh (-0.767 kW)
Last 7 Days 185.271 kWh (26.467 kWh/day) 93.847 kWh (13.407 kWh/day) -91.424 kWh (-13.061 kWh/day)
Last 30 Days (03/10/2026) 643.937 kWh (21.465 kWh/day) 441.987 kWh (14.733 kWh/day) -201.950 kWh (-6.732 kWh/day)
Last One Year 6.176 MWh (16.921 kWh/day) 7.826 MWh (21.440 kWh/day) 1.650 MWh (4.519 kWh/day)
Lifetime Since PTO 36.997 MWh (17.257 kW/day) 41.201 MWh (19.217 kW/day) 4.204 MWh (1.961 kW/day)
Lifetime Since Install 37.031 MWh 41.781 MWh 4.750 MWh
Voltage/Current 249.6 V / 1.3 A 249.5 V / 15.6 A 249.5 V / 14.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/01/2021 21:28 (8.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.281 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.112 0.378 0.174 4.108 0.000 kW
0.362 kWh
0.000 kW
2.170 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.104 0.344 0.154 3.785
03 - 202224****** IQ7+M [0] ---- 0.000 0.125 0.366 0.166 3.828
04 - 202232****** IQ7+ [0] ---- 0.000 0.125 0.373 0.170 3.781
05 - 202244****** IQ7+M [0] ---- 0.000 0.130 0.344 0.149 4.071
06 - 202245****** IQ7+M [0] ---- 0.000 0.130 0.364 0.162 4.231
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.155 0.342 0.159 5.317 0.000 kW
0.347 kWh
0.000 kW
1.736 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.073 0.293 0.158 4.767
09 - 202217****** IQ7+ [0] ---- 0.000 0.154 0.388 0.161 5.617
10 - 202244****** IQ7+M [0] ---- 0.000 0.160 0.385 0.163 5.585
11 - 202224****** IQ7+M [0] ---- 0.000 0.131 0.328 0.160 5.249
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.095 0.343 0.166 1.814 0.000 kW
0.344 kWh
0.000 kW
1.376 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.094 0.345 0.167 2.061
14 - 202216****** IQ7+ [0] ---- 0.000 0.094 0.348 0.170 2.057
15 - 202245****** IQ7+M [0] ---- 0.000 0.092 0.339 0.167 2.002
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.23 V Current/Power 166.23 A (8.848 kW)
Remain Capacity/Energy 490.8 Ah (25.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 83.0 % State Of Health 98.5 %
Run Time 36m to full Report Date 2021-01-01 23:33
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.23 V Cell (MIN/MAX) 3.321 V / 3.331 V (0.010 V)
Current/Power -0.27 A (-14 W) Runtime 25d 1h 28m to empty
Remain Capacity/Energy 163.6 Ah (8.4 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 83.0 % State Of Health 98.5 %
Temperature 18.5 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-01 23:33
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.321 V 3.322 V 3.323 V 3.323 V 3.324 V 3.325 V 3.325 V 3.326 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.327 V 3.327 V 3.328 V 3.329 V 3.329 V 3.330 V 3.331 V 3.331 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -