Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.227 kW
05/30/2026 17:05 (2194 days) Production Consumption NET Usage
Now 2.805 kW 0.578 kW -2.227 kW
Today 26.353 kWh (1.540 kW) 9.019 kWh (0.527 kW) -17.334 kWh (-1.013 kW)
  - This Week 184.968 kWh (27.557 kWh/day) 149.733 kWh (22.308 kWh/day) -35.235 kWh (-5.249 kWh/day)
  - This Month 746.963 kWh (25.140 kWh/day) 505.902 kWh (17.027 kWh/day) -241.061 kWh (-8.113 kWh/day)
  - This Year 2.700 MWh (18.035 kWh/day) 2.566 MWh (17.137 kWh/day) -0.134 MWh (-0.898 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 185.230 kWh (26.461 kWh/day) 152.637 kWh (21.805 kWh/day) -32.593 kWh (-4.656 kWh/day)
Last 30 Days (04/30/2026) 748.101 kWh (24.937 kWh/day) 508.947 kWh (16.965 kWh/day) -239.154 kWh (-7.972 kWh/day)
Last One Year 6.432 MWh (17.622 kWh/day) 7.838 MWh (21.473 kWh/day) 1.405 MWh (3.851 kWh/day)
Lifetime Since PTO 38.266 MWh (17.435 kW/day) 42.076 MWh (19.172 kW/day) 3.811 MWh (1.736 kW/day)
Lifetime Since Install 38.300 MWh 42.656 MWh 4.357 MWh
Voltage/Current 249.9 V / 11.2 A 249.8 V / 2.3 A 249.8 V / -8.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/23/2021 23:33 (9.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.647 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.091 0.167 0.035 2.611 0.000 kW
0.202 kWh
0.000 kW
1.214 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.043 0.111 0.030 2.517
03 - 202224****** IQ7+M [5] VCOP 0.000 0.044 0.119 0.034 2.588
04 - 202232****** IQ7+ [5] VCOP 0.000 0.054 0.133 0.043 2.578
05 - 202244****** IQ7+M [5] VCOP 0.000 0.148 0.323 0.205 3.149
06 - 202245****** IQ7+M [5] VCOP 0.000 0.146 0.361 0.214 3.128
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.168 0.253 0.209 5.232 0.000 kW
0.337 kWh
0.000 kW
1.687 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.170 0.226 0.205 4.291
09 - 202217****** IQ7+ [5] VCOP 0.000 0.178 0.334 0.209 5.623
10 - 202244****** IQ7+M [5] VCOP 0.000 0.173 0.554 0.216 5.712
11 - 202224****** IQ7+M [5] VCOP 0.000 0.170 0.319 0.209 5.211
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.112 0.256 0.030 1.603 0.000 kW
0.186 kWh
0.000 kW
0.745 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.084 0.165 0.027 1.651
14 - 202216****** IQ7+ [5] VCOP 0.000 0.044 0.124 0.020 1.651
15 - 202245****** IQ7+M [5] VCOP 0.000 0.097 0.200 0.035 1.649
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.88 V Current/Power 0.00 A (0 W)
Remain Capacity/Energy 492.6 Ah (25.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 83.4 % State Of Health 98.5 %
Run Time Stand-by Report Date 2021-02-23 23:10
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack