Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.081 kW
05/30/2026 18:12 (2194 days) Production Consumption NET Usage
Now 1.547 kW 0.466 kW -1.081 kW
Today 28.809 kWh (1.581 kW) 9.762 kWh (0.536 kW) -19.047 kWh (-1.045 kW)
  - This Week 187.424 kWh (27.731 kWh/day) 150.476 kWh (22.264 kWh/day) -36.948 kWh (-5.467 kWh/day)
  - This Month 749.419 kWh (25.183 kWh/day) 506.645 kWh (17.025 kWh/day) -242.774 kWh (-8.158 kWh/day)
  - This Year 2.702 MWh (18.045 kWh/day) 2.566 MWh (17.137 kWh/day) -0.136 MWh (-0.909 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 187.509 kWh (26.787 kWh/day) 153.085 kWh (21.869 kWh/day) -34.424 kWh (-4.918 kWh/day)
Last 30 Days (04/30/2026) 749.927 kWh (24.998 kWh/day) 508.508 kWh (16.950 kWh/day) -241.419 kWh (-8.047 kWh/day)
Last One Year 6.433 MWh (17.625 kWh/day) 7.837 MWh (21.471 kWh/day) 1.404 MWh (3.846 kWh/day)
Lifetime Since PTO 38.268 MWh (17.436 kW/day) 42.077 MWh (19.172 kW/day) 3.809 MWh (1.735 kW/day)
Lifetime Since Install 38.302 MWh 42.657 MWh 4.355 MWh
Voltage/Current 250.4 V / 6.2 A 250.3 V / 1.9 A 250.3 V / -4.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/23/2021 23:33 (9.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.647 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.091 0.167 0.035 2.611 0.000 kW
0.202 kWh
0.000 kW
1.214 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.043 0.111 0.030 2.517
03 - 202224****** IQ7+M [5] VCOP 0.000 0.044 0.119 0.034 2.588
04 - 202232****** IQ7+ [5] VCOP 0.000 0.054 0.133 0.043 2.578
05 - 202244****** IQ7+M [5] VCOP 0.000 0.148 0.323 0.205 3.149
06 - 202245****** IQ7+M [5] VCOP 0.000 0.146 0.361 0.214 3.128
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.168 0.253 0.209 5.232 0.000 kW
0.337 kWh
0.000 kW
1.687 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.170 0.226 0.205 4.291
09 - 202217****** IQ7+ [5] VCOP 0.000 0.178 0.334 0.209 5.623
10 - 202244****** IQ7+M [5] VCOP 0.000 0.173 0.554 0.216 5.712
11 - 202224****** IQ7+M [5] VCOP 0.000 0.170 0.319 0.209 5.211
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.112 0.256 0.030 1.603 0.000 kW
0.186 kWh
0.000 kW
0.745 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.084 0.165 0.027 1.651
14 - 202216****** IQ7+ [5] VCOP 0.000 0.044 0.124 0.020 1.651
15 - 202245****** IQ7+M [5] VCOP 0.000 0.097 0.200 0.035 1.649
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.