Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.030 kW
11/03/2025 10:22 (1986 days) Production Consumption NET Usage
Now 1.233 kW 0.203 kW -1.030 kW
Today 3.047 kWh (0.293 kW) 2.965 kWh (0.285 kW) -0.082 kWh (-0.008 kW)
  - This Week 20.218 kWh (14.113 kWh/day) 29.282 kWh (20.440 kWh/day) 9.064 kWh (6.327 kWh/day)
  - This Month 37.156 kWh (15.272 kWh/day) 45.470 kWh (18.689 kWh/day) 8.314 kWh (3.417 kWh/day)
  - This Year 5.615 MWh (18.324 kWh/day) 6.378 MWh (20.813 kWh/day) 0.763 MWh (2.489 kWh/day)
Yesterday 17.171 kWh (0.716 kW) 26.317 kWh (1.097 kW) 9.146 kWh (0.381 kW)
Last 7 Days 86.148 kWh (12.307 kWh/day) 98.955 kWh (14.137 kWh/day) 12.807 kWh (1.830 kWh/day)
Last 30 Days 441.432 kWh (14.715 kWh/day) 484.805 kWh (16.161 kWh/day) 43.373 kWh (1.446 kWh/day)
Last One Year 6.208 MWh (17.008 kWh/day) 7.431 MWh (20.358 kWh/day) 1.223 MWh (3.350 kWh/day)
Lifetime Since PTO 35.066 MWh (17.652 kW/day) 38.331 MWh (19.296 kW/day) 3.265 MWh (1.643 kW/day)
Lifetime Since Install 35.100 MWh 38.911 MWh 3.811 MWh
Voltage/Current 248.2 V / 5.0 A 248.2 V / 0.8 A 248.2 V / -4.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/10/2020 23:41 (13.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.188 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.908 1.734 10.262 0.000 kW
1.856 kWh
0.000 kW
11.134 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.852 1.680 10.006
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.891 1.717 10.162
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.906 1.728 10.191
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.742 1.569 9.548
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.836 1.667 9.991
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.753 1.593 9.549 0.000 kW
1.796 kWh
0.000 kW
8.981 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.806 1.611 9.691
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.764 1.607 9.612
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.826 1.642 9.801
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.833 1.644 9.777
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.258 1.795 1.592 9.492 0.000 kW
1.768 kWh
0.000 kW
7.072 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.253 1.716 1.543 9.197
14 - 202216****** IQ7+ [5] VCOP 0.000 0.258 1.795 1.597 9.538
15 - 202245****** IQ7+M [5] VCOP 0.000 0.254 1.766 1.570 9.392
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.62 V Current/Power 179.81 A (10.360 kW)
Remain Capacity/Energy 570.3 Ah (29.2 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.8 % State Of Health 96.2 %
Run Time 2m to full Report Date 2020-08-10 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.62 V Cell (MIN/MAX) 3.584 V / 3.608 V (0.024 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 190.1 Ah (9.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 98.8 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-10 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.598 V 3.601 V 3.600 V 3.584 V 3.600 V 3.605 V 3.601 V 3.602 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.600 V 3.589 V 3.602 V 3.602 V 3.603 V 3.608 V 3.607 V 3.607 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -