Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.153 kW
05/30/2026 18:08 (2194 days) Production Consumption NET Usage
Now 1.624 kW 0.471 kW -1.153 kW
Today 28.722 kWh (1.581 kW) 9.735 kWh (0.536 kW) -18.987 kWh (-1.045 kW)
  - This Week 187.337 kWh (27.727 kWh/day) 150.449 kWh (22.268 kWh/day) -36.888 kWh (-5.460 kWh/day)
  - This Month 749.332 kWh (25.182 kWh/day) 506.618 kWh (17.026 kWh/day) -242.714 kWh (-8.157 kWh/day)
  - This Year 2.702 MWh (18.045 kWh/day) 2.566 MWh (17.137 kWh/day) -0.136 MWh (-0.908 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 187.430 kWh (26.776 kWh/day) 153.095 kWh (21.871 kWh/day) -34.335 kWh (-4.905 kWh/day)
Last 30 Days (04/30/2026) 749.853 kWh (24.995 kWh/day) 508.489 kWh (16.950 kWh/day) -241.364 kWh (-8.045 kWh/day)
Last One Year 6.433 MWh (17.625 kWh/day) 7.837 MWh (21.471 kWh/day) 1.404 MWh (3.846 kWh/day)
Lifetime Since PTO 38.268 MWh (17.436 kW/day) 42.077 MWh (19.172 kW/day) 3.809 MWh (1.736 kW/day)
Lifetime Since Install 38.302 MWh 42.657 MWh 4.355 MWh
Voltage/Current 250.6 V / 6.5 A 250.5 V / 1.9 A 250.6 V / -4.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/13/2021 23:13 (11.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.588 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.294 2.002 1.755 11.896 0.000 kW
1.955 kWh
0.000 kW
11.732 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.950 1.711 11.565
03 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.989 1.742 11.809
04 - 202232****** IQ7+ [5] VCOP 0.000 0.294 1.980 1.735 11.767
05 - 202244****** IQ7+M [5] VCOP 0.000 0.288 1.911 1.692 11.444
06 - 202245****** IQ7+M [5] VCOP 0.000 0.288 1.900 1.689 11.443
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.301 2.081 1.889 12.641 0.000 kW
2.068 kWh
0.000 kW
10.342 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.301 1.914 1.763 11.698
09 - 202217****** IQ7+ [5] VCOP 0.000 0.301 2.092 1.883 12.742
10 - 202244****** IQ7+M [5] VCOP 0.000 0.300 2.131 1.927 12.944
11 - 202224****** IQ7+M [5] VCOP 0.000 0.301 2.124 1.919 12.844
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.213 1.391 1.106 8.134 0.000 kW
1.378 kWh
0.000 kW
5.514 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.210 1.357 1.080 8.038
14 - 202216****** IQ7+ [5] VCOP 0.000 0.210 1.397 1.116 8.221
15 - 202245****** IQ7+M [5] VCOP 0.000 0.208 1.368 1.092 8.058
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.12 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 437.1 Ah (22.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 74.0 % State Of Health 98.5 %
Run Time 12d 3h 24m to empty Report Date 2021-03-13 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.