Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.102 kW
02/08/2026 00:01 (2083 days) Production Consumption NET Usage
Now 0.317 kW 0.419 kW 0.102 kW
Today 0.008 kWh 0.010 kWh 0.002 kWh
  - This Week 0.008 kWh 0.010 kWh 0.002 kWh
  - This Month 111.840 kWh (15.973 kWh/day) 141.269 kWh (20.176 kWh/day) 29.429 kWh (4.203 kWh/day)
  - This Year 0.357 MWh (9.401 kWh/day) 0.724 MWh (19.064 kWh/day) 0.367 MWh (9.663 kWh/day)
Yesterday 17.851 kWh (0.744 kW) 11.028 kWh (0.460 kW) -6.823 kWh (-0.284 kW)
Last 7 Days 111.823 kWh (15.978 kWh/day) 141.248 kWh (20.183 kWh/day) 29.425 kWh (4.205 kWh/day)
Last 30 Days 291.104 kWh (9.704 kWh/day) 584.080 kWh (19.469 kWh/day) 292.976 kWh (9.766 kWh/day)
Last One Year 6.117 MWh (16.758 kWh/day) 7.573 MWh (20.748 kWh/day) 1.456 MWh (3.990 kWh/day)
Lifetime Since PTO 35.923 MWh (17.245 kW/day) 40.236 MWh (19.316 kW/day) 4.313 MWh (2.071 kW/day)
Lifetime Since Install 35.957 MWh 40.816 MWh 4.859 MWh
Voltage/Current 249.0 V / 1.3 A 248.9 V / 1.7 A 249.0 V / 0.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/25/2020 22:28 (9.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.286 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.253 0.443 0.987 5.770 0.000 kW
0.439 kWh
0.000 kW
2.636 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.250 0.435 0.952 5.635
03 - 202224****** IQ7+M [0] ---- 0.000 0.256 0.444 0.937 5.627
04 - 202232****** IQ7+ [0] ---- 0.000 0.210 0.414 0.901 5.444
05 - 202244****** IQ7+M [0] ---- 0.000 0.249 0.450 0.994 5.809
06 - 202245****** IQ7+M [0] ---- 0.000 0.250 0.450 0.984 5.758
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.288 0.442 1.189 6.784 0.000 kW
0.445 kWh
0.000 kW
2.223 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.286 0.385 1.161 6.403
09 - 202217****** IQ7+ [0] ---- 0.000 0.291 0.481 1.268 7.245
10 - 202244****** IQ7+M [0] ---- 0.000 0.291 0.483 1.262 7.205
11 - 202224****** IQ7+M [0] ---- 0.000 0.289 0.432 1.202 6.867
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.153 0.356 0.410 2.727 0.000 kW
0.357 kWh
0.000 kW
1.427 kWh
13 - 202223****** IQ7+ [0] V--- 0.000 0.159 0.358 0.477 3.065
14 - 202216****** IQ7+ [0] ---- 0.000 0.161 0.361 0.471 3.045
15 - 202245****** IQ7+M [0] ---- 0.000 0.157 0.353 0.457 2.963
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.40 V Current/Power 166.80 A (8.907 kW)
Remain Capacity/Energy 358.5 Ah (18.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 60.7 % State Of Health 98.5 %
Run Time 1h 23m to full Report Date 2020-11-25 21:43
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.