Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.259 kW
09/14/2025 08:11 (1936 days) Production Consumption NET Usage
Now 0.496 kW 0.237 kW -0.259 kW
Today 0.352 kWh (0.043 kW) 3.299 kWh (0.401 kW) 2.947 kWh (0.359 kW)
  - This Week 0.352 kWh (1.028 kWh/day) 3.299 kWh (9.635 kWh/day) 2.947 kWh (8.607 kWh/day)
  - This Month 286.121 kWh (21.446 kWh/day) 307.856 kWh (23.075 kWh/day) 21.735 kWh (1.629 kWh/day)
  - This Year 4.793 MWh (18.699 kWh/day) 5.479 MWh (21.372 kWh/day) 0.685 MWh (2.673 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.244 MWh (17.685 kW/day) 37.431 MWh (19.331 kW/day) 3.186 MWh (1.645 kW/day)
Lifetime Since Install 34.278 MWh 38.011 MWh 3.732 MWh
Voltage/Current 253.5 V / 2.0 A 253.5 V / 0.9 A 253.5 V / -1.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/06/2020 20:42 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 21.431 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.293 1.512 2.262 12.837 0.000 kW
1.424 kWh
0.000 kW
8.542 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.444 2.213 12.480
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.425 2.208 12.483
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.449 2.220 12.506
05 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.246 2.019 11.626
06 - 202245****** IQ7+M [5] VCOP 0.000 0.290 1.467 2.223 12.562
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.288 1.230 1.995 11.361 0.000 kW
1.253 kWh
0.000 kW
6.266 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.287 1.261 2.076 11.738
09 - 202217****** IQ7+ [5] VCOP 0.000 0.285 1.247 2.025 11.561
10 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.268 2.077 11.825
11 - 202224****** IQ7+M [5] VCOP 0.000 0.285 1.259 2.076 11.789
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.260 1.660 2.062 12.572 0.000 kW
1.656 kWh
0.000 kW
6.622 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.264 1.652 1.990 12.284
14 - 202216****** IQ7+ [5] VCOP 0.000 0.264 1.667 2.064 12.612
15 - 202245****** IQ7+M [5] VCOP 0.000 0.257 1.643 2.027 12.381
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.41 V Current/Power 178.54 A (10.071 kW)
Remain Capacity/Energy 577.2 Ah (29.6 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 100.0 % State Of Health 96.2 %
Run Time - to full Report Date 2020-07-06 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.