Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.955 kW
07/17/2026 09:22 (2242 days) Production Consumption NET Usage
Now 1.568 kW 0.613 kW -0.955 kW
Today 4.768 kWh (0.508 kW) 4.638 kWh (0.494 kW) -0.130 kWh (-0.014 kW)
  - This Week 150.795 kWh (27.972 kWh/day) 173.579 kWh (32.198 kWh/day) 22.784 kWh (4.226 kWh/day)
  - This Month 421.349 kWh (25.705 kWh/day) 571.542 kWh (34.868 kWh/day) 150.193 kWh (9.163 kWh/day)
  - This Year 4.031 MWh (20.422 kWh/day) 3.858 MWh (19.547 kWh/day) -0.173 MWh (-0.876 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 198.955 kWh (28.422 kWh/day) 236.701 kWh (33.814 kWh/day) 37.746 kWh (5.392 kWh/day)
Last 30 Days (06/17/2026) 743.109 kWh (24.770 kWh/day) 866.785 kWh (28.893 kWh/day) 123.676 kWh (4.123 kWh/day)
Last One Year 6.732 MWh (18.443 kWh/day) 7.644 MWh (20.942 kWh/day) 0.912 MWh (2.499 kWh/day)
Lifetime Since PTO 39.597 MWh (17.658 kW/day) 43.369 MWh (19.341 kW/day) 3.772 MWh (1.682 kW/day)
Lifetime Since Install 39.631 MWh 43.949 MWh 4.318 MWh
Voltage/Current 248.7 V / 6.3 A 248.8 V / 2.5 A 248.7 V / -3.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/08/2021 20:05 (13.6 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.093 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.281 0.632 1.770 10.440 0.000 kW
0.619 kWh
0.000 kW
3.711 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.281 0.610 1.686 10.078
03 - 202224****** IQ7+M [5] VCOP 0.000 0.277 0.633 1.728 10.295
04 - 202232****** IQ7+ [5] VCOP 0.000 0.280 0.628 1.767 10.386
05 - 202244****** IQ7+M [5] VCOP 0.000 0.281 0.596 1.541 9.580
06 - 202245****** IQ7+M [5] VCOP 0.000 0.286 0.612 1.682 10.022
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.284 0.572 1.578 9.726 0.000 kW
0.574 kWh
0.000 kW
2.870 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.280 0.567 1.539 9.749
09 - 202217****** IQ7+ [5] VCOP 0.000 0.276 0.576 1.576 9.788
10 - 202244****** IQ7+M [5] VCOP 0.000 0.271 0.583 1.588 9.959
11 - 202224****** IQ7+M [5] VCOP 0.000 0.270 0.572 1.575 9.925
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.266 0.624 1.980 10.241 0.000 kW
0.628 kWh
0.000 kW
2.513 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.261 0.626 1.972 9.949
14 - 202216****** IQ7+ [5] VCOP 0.000 0.264 0.637 1.997 10.282
15 - 202245****** IQ7+M [5] VCOP 0.000 0.265 0.626 1.977 10.132
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.18 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 505.5 Ah (25.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 84.3 % State Of Health 100.0 %
Run Time 17d 13h 14m to empty Report Date 2021-05-08 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.22 V Cell (MIN/MAX) 3.321 V / 3.330 V (0.009 V)
Current/Power -0.50 A (-26 W) Runtime 14d 1h 0m to empty
Remain Capacity/Energy 168.5 Ah (8.6 kWh) Full Capacity/Energy 200.0 Ah (10.2 kWh)
State Of Charge 84.2 % State Of Health 100.0 %
Temperature 21.0 °C Cycle 38
MOSFET CFET = ON, DFET = ON Reported 2021-05-08 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.321 V 3.321 V 3.322 V 3.323 V 3.324 V 3.324 V 3.325 V 3.325 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.327 V 3.327 V 3.328 V 3.328 V 3.329 V 3.330 V 3.330 V 3.330 V
pack voltage and current cell voltages
pack temperature
JpGraph Error: 25107 Can't write to file "images/chart_batt2_1.png". Check that the process running PHP has enough permission.