Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.422 kW
07/17/2026 10:06 (2242 days) Production Consumption NET Usage
Now 2.806 kW 0.384 kW -2.422 kW
Today 6.421 kWh (0.635 kW) 5.133 kWh (0.508 kW) -1.288 kWh (-0.127 kW)
  - This Week 152.448 kWh (28.122 kWh/day) 174.074 kWh (32.112 kWh/day) 21.626 kWh (3.989 kWh/day)
  - This Month 423.002 kWh (25.759 kWh/day) 572.037 kWh (34.834 kWh/day) 149.035 kWh (9.076 kWh/day)
  - This Year 4.033 MWh (20.428 kWh/day) 3.859 MWh (19.546 kWh/day) -0.174 MWh (-0.881 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 199.183 kWh (28.455 kWh/day) 236.249 kWh (33.750 kWh/day) 37.066 kWh (5.295 kWh/day)
Last 30 Days (06/17/2026) 743.204 kWh (24.773 kWh/day) 866.902 kWh (28.897 kWh/day) 123.698 kWh (4.123 kWh/day)
Last One Year 6.732 MWh (18.445 kWh/day) 7.644 MWh (20.943 kWh/day) 0.912 MWh (2.498 kWh/day)
Lifetime Since PTO 39.599 MWh (17.659 kW/day) 43.370 MWh (19.341 kW/day) 3.771 MWh (1.682 kW/day)
Lifetime Since Install 39.632 MWh 43.950 MWh 4.317 MWh
Voltage/Current 249.2 V / 11.3 A 249.3 V / 1.5 A 249.3 V / -9.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/12/2021 20:17 (14.1 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 32.494 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.259 1.991 9.431 0.000 kW
2.171 kWh
0.000 kW
13.024 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.301 2.166 1.895 9.023
03 - 202224****** IQ7+M [5] VCOP 0.000 0.301 2.191 1.910 9.227
04 - 202232****** IQ7+ [5] VCOP 0.000 0.300 2.227 1.948 9.322
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.000 1.730 8.420
06 - 202245****** IQ7+M [5] VCOP 0.000 0.299 2.181 1.908 9.030
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.300 2.027 1.749 8.453 0.000 kW
2.058 kWh
0.000 kW
10.291 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.301 2.059 1.757 8.374
09 - 202217****** IQ7+ [5] VCOP 0.000 0.302 2.047 1.754 8.506
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.079 1.790 8.594
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 2.079 1.804 8.563
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.280 2.335 2.097 9.895 0.000 kW
2.295 kWh
0.000 kW
9.179 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.274 2.242 2.039 9.748
14 - 202216****** IQ7+ [5] VCOP 0.000 0.275 2.316 2.090 9.935
15 - 202245****** IQ7+M [5] VCOP 0.000 0.273 2.286 2.066 9.811
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 523.5 Ah (26.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.2 % State Of Health 100.0 %
Run Time 24d 5h 40m to empty Report Date 2021-05-12 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.