Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 9.449 kW
12/18/2025 14:51 (2031 days) Production Consumption NET Usage
Now 0.577 kW 10.026 kW 9.449 kW
Today 12.008 kWh (0.808 kW) 9.373 kWh (0.631 kW) -2.635 kWh (-0.177 kW)
  - This Week 38.016 kWh (8.228 kWh/day) 75.322 kWh (16.302 kWh/day) 37.306 kWh (8.074 kWh/day)
  - This Month 158.767 kWh (9.011 kWh/day) 336.595 kWh (19.103 kWh/day) 177.828 kWh (10.093 kWh/day)
  - This Year 6.028 MWh (17.143 kWh/day) 7.253 MWh (20.627 kWh/day) 1.225 MWh (3.484 kWh/day)
Yesterday 7.005 kWh (0.292 kW) 16.287 kWh (0.679 kW) 9.282 kWh (0.387 kW)
Last 7 Days 56.453 kWh (7.657 kWh/day) 154.901 kWh (21.010 kWh/day) 98.448 kWh (13.353 kWh/day)
Last 30 Days 257.930 kWh (8.597 kWh/day) 567.163 kWh (18.905 kWh/day) 309.233 kWh (10.308 kWh/day)
Last One Year 6.108 MWh (16.733 kWh/day) 7.581 MWh (20.770 kWh/day) 1.473 MWh (4.037 kWh/day)
Lifetime Since PTO 35.479 MWh (17.463 kW/day) 39.206 MWh (19.297 kW/day) 3.727 MWh (1.834 kW/day)
Lifetime Since Install 35.513 MWh 39.786 MWh 4.273 MWh
Voltage/Current 247.7 V / 2.3 A 247.8 V / 40.5 A 247.8 V / 38.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/24/2020 22:28 (3.5 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 1.963 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.046 0.138 0.631 5.850 0.000 kW
0.136 kWh
0.000 kW
0.814 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.045 0.134 0.623 5.757
03 - 202224****** IQ7+M [5] VCOP 0.000 0.048 0.139 0.639 5.846
04 - 202232****** IQ7+ [5] VCOP 0.000 0.045 0.135 0.631 5.785
05 - 202244****** IQ7+M [5] VCOP 0.000 0.045 0.134 0.629 5.788
06 - 202245****** IQ7+M [5] VCOP 0.000 0.045 0.134 0.627 5.789
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.042 0.122 0.704 6.268 0.000 kW
0.123 kWh
0.000 kW
0.615 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.043 0.123 0.710 5.919
09 - 202217****** IQ7+ [5] VCOP 0.000 0.043 0.123 0.728 6.476
10 - 202244****** IQ7+M [5] VCOP 0.000 0.043 0.124 0.731 6.524
11 - 202224****** IQ7+M [5] VCOP 0.000 0.043 0.123 0.723 6.420
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.043 0.133 0.423 4.059 0.000 kW
0.133 kWh
0.000 kW
0.534 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.044 0.133 0.435 4.139
14 - 202216****** IQ7+ [5] VCOP 0.000 0.045 0.135 0.442 4.198
15 - 202245****** IQ7+M [5] VCOP 0.000 0.043 0.133 0.432 4.122
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.01 V Current/Power 175.11 A (9.808 kW)
Remain Capacity/Energy 531.6 Ah (27.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 89.9 % State Of Health 98.5 %
Run Time 20m to full Report Date 2020-10-23 15:17
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.01 V Cell (MIN/MAX) 3.495 V / 3.505 V (0.010 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 177.2 Ah (9.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 89.9 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-10-23 15:17
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.499 V 3.497 V 3.503 V 3.500 V 3.502 V 3.498 V 3.505 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.499 V 3.502 V 3.502 V 3.501 V 3.502 V 3.498 V 3.505 V 3.505 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -