Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.955 kW
07/17/2026 09:22 (2242 days) Production Consumption NET Usage
Now 1.568 kW 0.613 kW -0.955 kW
Today 4.768 kWh (0.508 kW) 4.638 kWh (0.494 kW) -0.130 kWh (-0.014 kW)
  - This Week 150.795 kWh (27.972 kWh/day) 173.579 kWh (32.198 kWh/day) 22.784 kWh (4.226 kWh/day)
  - This Month 421.349 kWh (25.705 kWh/day) 571.542 kWh (34.868 kWh/day) 150.193 kWh (9.163 kWh/day)
  - This Year 4.031 MWh (20.422 kWh/day) 3.858 MWh (19.547 kWh/day) -0.173 MWh (-0.876 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 198.984 kWh (28.426 kWh/day) 236.747 kWh (33.821 kWh/day) 37.763 kWh (5.395 kWh/day)
Last 30 Days (06/17/2026) 743.140 kWh (24.771 kWh/day) 866.787 kWh (28.893 kWh/day) 123.647 kWh (4.122 kWh/day)
Last One Year 6.732 MWh (18.443 kWh/day) 7.644 MWh (20.942 kWh/day) 0.912 MWh (2.499 kWh/day)
Lifetime Since PTO 39.597 MWh (17.658 kW/day) 43.369 MWh (19.341 kW/day) 3.772 MWh (1.682 kW/day)
Lifetime Since Install 39.631 MWh 43.949 MWh 4.318 MWh
Voltage/Current 248.7 V / 6.3 A 248.8 V / 2.5 A 248.7 V / -3.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/31/2021 20:28 (14.3 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.250 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.298 1.582 0.292 9.713 0.000 kW
1.554 kWh
0.000 kW
9.327 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.545 0.275 9.406
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.578 0.291 9.547
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.556 0.287 9.589
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.525 0.269 8.877
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.540 0.278 9.449
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.425 0.261 8.864 0.000 kW
1.519 kWh
0.000 kW
7.593 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.541 0.257 8.942
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.501 0.263 8.962
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.556 0.266 9.077
11 - 202224****** IQ7+M [5] VCOP 0.000 0.299 1.570 0.262 9.075
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.288 1.353 0.285 9.598 0.000 kW
1.333 kWh
0.000 kW
5.331 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.283 1.276 0.287 9.362
14 - 202216****** IQ7+ [5] VCOP 0.000 0.286 1.364 0.293 9.623
15 - 202245****** IQ7+M [5] VCOP 0.000 0.286 1.338 0.287 9.513
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.22 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 536.4 Ah (27.5 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 89.4 % State Of Health 100.0 %
Run Time 18d 14h 59m to empty Report Date 2021-05-31 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.