Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.992 kW
12/18/2025 13:41 (2031 days) Production Consumption NET Usage
Now 1.203 kW 0.211 kW -0.992 kW
Today 10.171 kWh (0.743 kW) 7.286 kWh (0.532 kW) -2.885 kWh (-0.211 kW)
  - This Week 36.179 kWh (7.914 kWh/day) 73.235 kWh (16.020 kWh/day) 37.056 kWh (8.106 kWh/day)
  - This Month 156.930 kWh (8.931 kWh/day) 334.508 kWh (19.038 kWh/day) 177.578 kWh (10.106 kWh/day)
  - This Year 6.026 MWh (17.140 kWh/day) 7.251 MWh (20.624 kWh/day) 1.225 MWh (3.484 kWh/day)
Yesterday 7.005 kWh (0.292 kW) 16.287 kWh (0.679 kW) 9.282 kWh (0.387 kW)
Last 7 Days 56.453 kWh (7.657 kWh/day) 154.901 kWh (21.010 kWh/day) 98.448 kWh (13.353 kWh/day)
Last 30 Days 257.930 kWh (8.597 kWh/day) 567.163 kWh (18.905 kWh/day) 309.233 kWh (10.308 kWh/day)
Last One Year 6.108 MWh (16.733 kWh/day) 7.581 MWh (20.770 kWh/day) 1.473 MWh (4.037 kWh/day)
Lifetime Since PTO 35.477 MWh (17.462 kW/day) 39.204 MWh (19.297 kW/day) 3.727 MWh (1.834 kW/day)
Lifetime Since Install 35.511 MWh 39.784 MWh 4.273 MWh
Voltage/Current 250.7 V / 4.8 A 250.8 V / 0.8 A 250.8 V / -4.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/03/2020 23:16 (10.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.074 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.242 0.824 1.242 4.181 0.000 kW
0.812 kWh
0.000 kW
4.874 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.239 0.795 1.190 4.025
03 - 202224****** IQ7+M [5] VCOP 0.000 0.244 0.810 1.187 4.111
04 - 202232****** IQ7+ [5] VCOP 0.000 0.239 0.799 1.184 4.067
05 - 202244****** IQ7+M [5] VCOP 0.000 0.241 0.810 1.223 4.110
06 - 202245****** IQ7+M [5] VCOP 0.000 0.240 0.836 1.257 4.187
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 0.968 1.480 4.589 0.000 kW
0.979 kWh
0.000 kW
4.896 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.288 0.901 1.415 4.350
09 - 202217****** IQ7+ [5] VCOP 0.000 0.289 1.018 1.557 4.801
10 - 202244****** IQ7+M [5] VCOP 0.000 0.290 1.019 1.556 4.804
11 - 202224****** IQ7+M [5] VCOP 0.000 0.290 0.989 1.515 4.646
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.149 0.564 0.633 2.707 0.000 kW
0.576 kWh
0.000 kW
2.304 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.143 0.580 0.695 2.839
14 - 202216****** IQ7+ [5] VCOP 0.000 0.151 0.585 0.698 2.887
15 - 202245****** IQ7+M [5] VCOP 0.000 0.158 0.575 0.686 2.826
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.03 V Current/Power 178.09 A (10.156 kW)
Remain Capacity/Energy 586.8 Ah (30.0 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.3 % State Of Health 98.5 %
Run Time 1m to full Report Date 2020-11-03 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.03 V Cell (MIN/MAX) 3.553 V / 3.570 V (0.017 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 195.6 Ah (10.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.3 % State Of Health 98.5 %
Temperature 23.0 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-03 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.561 V 3.564 V 3.558 V 3.561 V 3.563 V 3.564 V 3.564 V 3.553 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.555 V 3.567 V 3.565 V 3.565 V 3.569 V 3.570 V 3.570 V 3.570 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -