Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.078 kW
02/07/2026 22:45 (2082 days) Production Consumption NET Usage
Now 0.317 kW 0.395 kW 0.078 kW
Today 17.457 kWh (0.767 kW) 10.544 kWh (0.463 kW) -6.913 kWh (-0.304 kW)
  - This Week 111.438 kWh (16.037 kWh/day) 140.775 kWh (20.259 kWh/day) 29.337 kWh (4.222 kWh/day)
  - This Month 111.438 kWh (16.037 kWh/day) 140.775 kWh (20.259 kWh/day) 29.337 kWh (4.222 kWh/day)
  - This Year 0.357 MWh (9.404 kWh/day) 0.724 MWh (19.078 kWh/day) 0.367 MWh (9.674 kWh/day)
Yesterday 11.310 kWh (0.471 kW) 14.055 kWh (0.586 kW) 2.745 kWh (0.114 kW)
Last 7 Days 111.824 kWh (18.479 kWh/day) 141.253 kWh (23.342 kWh/day) 29.429 kWh (4.863 kWh/day)
Last 30 Days 273.253 kWh (9.406 kWh/day) 583.984 kWh (20.101 kWh/day) 310.731 kWh (10.696 kWh/day)
Last One Year 6.099 MWh (16.752 kWh/day) 7.562 MWh (20.773 kWh/day) 1.464 MWh (4.021 kWh/day)
Lifetime Since PTO 35.923 MWh (17.246 kW/day) 40.235 MWh (19.316 kW/day) 4.313 MWh (2.071 kW/day)
Lifetime Since Install 35.956 MWh 40.815 MWh 4.859 MWh
Voltage/Current 248.8 V / 1.3 A 248.8 V / 1.6 A 248.8 V / 0.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/02/2021 20:51 (8.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.944 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.229 0.700 0.378 4.407 0.000 kW
0.688 kWh
0.000 kW
4.125 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.223 0.668 0.344 4.063
03 - 202224****** IQ7+M [0] ---- 0.000 0.231 0.683 0.366 4.119
04 - 202232****** IQ7+ [0] ---- 0.000 0.229 0.662 0.373 4.077
05 - 202244****** IQ7+M [0] ---- 0.000 0.225 0.699 0.344 4.352
06 - 202245****** IQ7+M [0] ---- 0.000 0.226 0.713 0.364 4.524
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 0.882 0.342 5.589 0.000 kW
0.900 kWh
0.000 kW
4.499 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 0.793 0.293 4.989
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 0.967 0.388 5.933
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 0.958 0.385 5.897
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 0.898 0.328 5.506
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.095 0.311 0.343 2.079 0.000 kW
0.330 kWh
0.000 kW
1.320 kWh
13 - 202223****** IQ7+ [0] V--- 0.000 0.106 0.339 0.345 2.327
14 - 202216****** IQ7+ [0] ---- 0.000 0.108 0.339 0.348 2.325
15 - 202245****** IQ7+M [0] ---- 0.000 0.100 0.330 0.339 2.264
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.