Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.120 kW
11/02/2025 07:40 (1985 days) Production Consumption NET Usage
Now 0.304 kW 0.424 kW 0.120 kW
Today 0.162 kWh (0.021 kW) 3.029 kWh (0.394 kW) 2.867 kWh (0.373 kW)
  - This Week 0.162 kWh (0.506 kWh/day) 3.029 kWh (9.459 kWh/day) 2.867 kWh (8.953 kWh/day)
  - This Month 17.100 kWh (12.949 kWh/day) 19.217 kWh (14.552 kWh/day) 2.117 kWh (1.603 kWh/day)
  - This Year 5.595 MWh (18.325 kWh/day) 6.352 MWh (20.803 kWh/day) 0.757 MWh (2.478 kWh/day)
Yesterday 16.938 kWh (0.705 kW) 16.188 kWh (0.674 kW) -0.750 kWh (-0.031 kW)
Last 7 Days 84.554 kWh (12.079 kWh/day) 68.911 kWh (9.845 kWh/day) -15.643 kWh (-2.235 kWh/day)
Last 30 Days 448.063 kWh (14.935 kWh/day) 470.286 kWh (15.676 kWh/day) 22.223 kWh (0.741 kWh/day)
Last One Year 6.208 MWh (17.009 kWh/day) 7.413 MWh (20.310 kWh/day) 1.205 MWh (3.301 kWh/day)
Lifetime Since PTO 35.046 MWh (17.652 kW/day) 38.304 MWh (19.293 kW/day) 3.258 MWh (1.641 kW/day)
Lifetime Since Install 35.080 MWh 38.884 MWh 3.804 MWh
Voltage/Current 249.8 V / 1.2 A 249.9 V / 1.7 A 249.8 V / 0.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/30/2020 21:50 (11.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 23.345 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.287 1.681 0.308 7.116 0.000 kW
1.671 kWh
0.000 kW
10.028 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.284 1.664 0.304 7.150
03 - 202224****** IQ7+M [5] VCOP 0.000 0.285 1.686 0.312 7.101
04 - 202232****** IQ7+ [5] VCOP 0.000 0.284 1.676 0.307 7.130
05 - 202244****** IQ7+M [5] VCOP 0.000 0.285 1.669 0.299 7.069
06 - 202245****** IQ7+M [5] VCOP 0.000 0.283 1.652 0.304 7.079
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.828 0.274 7.416 0.000 kW
1.815 kWh
0.000 kW
9.073 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.768 0.274 7.063
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.813 0.277 7.389
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.835 0.280 7.406
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.830 0.277 7.394
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.211 1.065 0.302 5.588 0.000 kW
1.061 kWh
0.000 kW
4.243 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.211 1.046 0.305 5.539
14 - 202216****** IQ7+ [5] VCOP 0.000 0.212 1.077 0.310 5.638
15 - 202245****** IQ7+M [5] VCOP 0.000 0.202 1.056 0.305 5.637
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.02 V Current/Power 175.05 A (9.807 kW)
Remain Capacity/Energy 567.9 Ah (29.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 96.1 % State Of Health 98.5 %
Run Time 7m to full Report Date 2020-09-30 23:10
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.02 V Cell (MIN/MAX) 3.494 V / 3.508 V (0.014 V)
Current/Power -0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 189.3 Ah (9.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 96.1 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-30 23:10
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.494 V 3.499 V 3.494 V 3.500 V 3.500 V 3.502 V 3.502 V 3.502 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.501 V 3.502 V 3.500 V 3.500 V 3.502 V 3.504 V 3.506 V 3.508 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -