Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.793 kW
11/02/2025 12:52 (1985 days) Production Consumption NET Usage
Now 2.956 kW 0.163 kW -2.793 kW
Today 11.586 kWh (0.900 kW) 5.704 kWh (0.443 kW) -5.882 kWh (-0.457 kW)
  - This Week 11.586 kWh (21.594 kWh/day) 5.704 kWh (10.631 kWh/day) -5.882 kWh (-10.963 kWh/day)
  - This Month 28.524 kWh (18.559 kWh/day) 21.892 kWh (14.244 kWh/day) -6.632 kWh (-4.315 kWh/day)
  - This Year 5.606 MWh (18.350 kWh/day) 6.354 MWh (20.797 kWh/day) 0.748 MWh (2.448 kWh/day)
Yesterday 16.938 kWh (0.705 kW) 16.188 kWh (0.674 kW) -0.750 kWh (-0.031 kW)
Last 7 Days 84.554 kWh (12.079 kWh/day) 68.911 kWh (9.845 kWh/day) -15.643 kWh (-2.235 kWh/day)
Last 30 Days 448.063 kWh (14.935 kWh/day) 470.286 kWh (15.676 kWh/day) 22.223 kWh (0.741 kWh/day)
Last One Year 6.208 MWh (17.009 kWh/day) 7.413 MWh (20.310 kWh/day) 1.205 MWh (3.301 kWh/day)
Lifetime Since PTO 35.057 MWh (17.656 kW/day) 38.307 MWh (19.293 kW/day) 3.250 MWh (1.637 kW/day)
Lifetime Since Install 35.091 MWh 38.887 MWh 3.796 MWh
Voltage/Current 250.0 V / 11.8 A 250.0 V / 0.7 A 250.0 V / -11.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/07/2020 21:39 (11.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.719 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.259 0.898 1.646 9.709 0.000 kW
0.884 kWh
0.000 kW
5.301 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.257 0.886 1.624 9.585
03 - 202224****** IQ7+M [5] VCOP 0.000 0.256 0.897 1.647 9.706
04 - 202232****** IQ7+ [5] VCOP 0.000 0.259 0.888 1.633 9.625
05 - 202244****** IQ7+M [5] VCOP 0.000 0.260 0.866 1.616 9.493
06 - 202245****** IQ7+M [5] VCOP 0.000 0.257 0.866 1.607 9.425
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 0.865 1.764 10.034 0.000 kW
0.851 kWh
0.000 kW
4.253 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.290 0.737 1.647 9.353
09 - 202217****** IQ7+ [5] VCOP 0.000 0.291 0.868 1.786 10.177
10 - 202244****** IQ7+M [5] VCOP 0.000 0.291 0.897 1.816 10.297
11 - 202224****** IQ7+M [5] VCOP 0.000 0.289 0.885 1.801 10.216
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.194 0.793 1.091 7.087 0.000 kW
0.791 kWh
0.000 kW
3.165 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.191 0.791 1.083 7.007
14 - 202216****** IQ7+ [5] VCOP 0.000 0.192 0.796 1.105 7.122
15 - 202245****** IQ7+M [5] VCOP 0.000 0.190 0.784 1.084 6.988
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.02 V Current/Power 175.03 A (9.806 kW)
Remain Capacity/Energy 562.8 Ah (28.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 95.2 % State Of Health 98.5 %
Run Time 9m to full Report Date 2020-10-07 23:12
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.02 V Cell (MIN/MAX) 3.495 V / 3.507 V (0.012 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 187.6 Ah (9.6 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 95.2 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-10-07 23:12
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.499 V 3.497 V 3.502 V 3.501 V 3.501 V 3.499 V 3.501 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.501 V 3.500 V 3.503 V 3.502 V 3.501 V 3.504 V 3.506 V 3.507 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -