Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 9.419 kW
12/18/2025 14:54 (2031 days) Production Consumption NET Usage
Now 0.531 kW 9.950 kW 9.419 kW
Today 12.033 kWh (0.807 kW) 9.822 kWh (0.659 kW) -2.211 kWh (-0.148 kW)
  - This Week 38.041 kWh (8.230 kWh/day) 75.771 kWh (16.393 kWh/day) 37.730 kWh (8.163 kWh/day)
  - This Month 158.792 kWh (9.011 kWh/day) 337.044 kWh (19.127 kWh/day) 178.252 kWh (10.116 kWh/day)
  - This Year 6.028 MWh (17.143 kWh/day) 7.253 MWh (20.628 kWh/day) 1.226 MWh (3.486 kWh/day)
Yesterday 7.005 kWh (0.292 kW) 16.287 kWh (0.679 kW) 9.282 kWh (0.387 kW)
Last 7 Days 56.453 kWh (7.657 kWh/day) 154.901 kWh (21.010 kWh/day) 98.448 kWh (13.353 kWh/day)
Last 30 Days 257.930 kWh (8.597 kWh/day) 567.163 kWh (18.905 kWh/day) 309.233 kWh (10.308 kWh/day)
Last One Year 6.108 MWh (16.733 kWh/day) 7.581 MWh (20.770 kWh/day) 1.473 MWh (4.037 kWh/day)
Lifetime Since PTO 35.479 MWh (17.463 kW/day) 39.206 MWh (19.298 kW/day) 3.727 MWh (1.835 kW/day)
Lifetime Since Install 35.513 MWh 39.786 MWh 4.274 MWh
Voltage/Current 247.6 V / 2.1 A 247.5 V / 40.2 A 247.6 V / 38.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/28/2020 20:45 (9.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 7.410 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.219 0.514 0.569 4.144 0.000 kW
0.508 kWh
0.000 kW
3.048 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.214 0.490 0.539 4.023
03 - 202224****** IQ7+M [5] VCOP 0.000 0.197 0.482 0.520 4.009
04 - 202232****** IQ7+ [5] VCOP 0.000 0.196 0.463 0.478 3.841
05 - 202244****** IQ7+M [5] VCOP 0.000 0.202 0.549 0.602 4.205
06 - 202245****** IQ7+M [5] VCOP 0.000 0.212 0.549 0.602 4.181
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.257 0.588 0.600 4.737 0.000 kW
0.581 kWh
0.000 kW
2.903 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.260 0.457 0.453 4.408
09 - 202217****** IQ7+ [5] VCOP 0.000 0.258 0.643 0.668 5.029
10 - 202244****** IQ7+M [5] VCOP 0.000 0.266 0.638 0.669 5.025
11 - 202224****** IQ7+M [5] VCOP 0.000 0.264 0.577 0.581 4.754
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.100 0.360 0.405 2.315 0.000 kW
0.365 kWh
0.000 kW
1.459 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.111 0.368 0.414 2.503
14 - 202216****** IQ7+ [5] VCOP 0.000 0.111 0.370 0.416 2.501
15 - 202245****** IQ7+M [5] VCOP 0.000 0.107 0.361 0.405 2.438
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.02 V Current/Power 178.06 A (10.154 kW)
Remain Capacity/Energy 589.8 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Run Time - to full Report Date 2020-11-28 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.02 V Cell (MIN/MAX) 3.552 V / 3.570 V (0.018 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 196.6 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Temperature 24.0 °C Cycle 27
MOSFET CFET = ON, DFET = ON Reported 2020-11-28 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.558 V 3.560 V 3.560 V 3.562 V 3.566 V 3.552 V 3.565 V 3.567 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.563 V 3.565 V 3.556 V 3.566 V 3.568 V 3.570 V 3.570 V 3.568 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -