Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.659 kW
05/30/2026 16:00 (2194 days) Production Consumption NET Usage
Now 1.238 kW 0.579 kW -0.659 kW
Today 23.600 kWh (1.473 kW) 8.040 kWh (0.502 kW) -15.560 kWh (-0.971 kW)
  - This Week 182.215 kWh (27.331 kWh/day) 148.754 kWh (22.312 kWh/day) -33.461 kWh (-5.019 kWh/day)
  - This Month 744.210 kWh (25.085 kWh/day) 504.923 kWh (17.020 kWh/day) -239.287 kWh (-8.066 kWh/day)
  - This Year 2.697 MWh (18.022 kWh/day) 2.565 MWh (17.136 kWh/day) -0.133 MWh (-0.886 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 182.753 kWh (26.108 kWh/day) 152.355 kWh (21.765 kWh/day) -30.398 kWh (-4.343 kWh/day)
Last 30 Days (04/30/2026) 746.431 kWh (24.881 kWh/day) 508.469 kWh (16.949 kWh/day) -237.962 kWh (-7.932 kWh/day)
Last One Year 6.432 MWh (17.622 kWh/day) 7.837 MWh (21.471 kWh/day) 1.405 MWh (3.850 kWh/day)
Lifetime Since PTO 38.263 MWh (17.435 kW/day) 42.075 MWh (19.172 kW/day) 3.812 MWh (1.737 kW/day)
Lifetime Since Install 38.297 MWh 42.655 MWh 4.359 MWh
Voltage/Current 249.7 V / 5.0 A 249.7 V / 2.3 A 249.7 V / -2.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/11/2021 20:19 (13.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.526 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.300 1.991 0.956 8.889 0.000 kW
1.897 kWh
0.000 kW
11.381 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.303 1.895 0.927 8.549
03 - 202224****** IQ7+M [5] VCOP 0.000 0.302 1.910 0.957 8.755
04 - 202232****** IQ7+ [5] VCOP 0.000 0.302 1.948 0.945 8.816
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.730 0.909 8.095
06 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.908 0.926 8.542
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.749 0.842 8.102 0.000 kW
1.771 kWh
0.000 kW
8.854 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.299 1.757 0.847 8.038
09 - 202217****** IQ7+ [5] VCOP 0.000 0.299 1.754 0.857 8.156
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.790 0.867 8.248
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.804 0.875 8.196
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.294 2.097 0.929 9.063 0.000 kW
2.073 kWh
0.000 kW
8.292 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.293 2.039 0.932 8.937
14 - 202216****** IQ7+ [5] VCOP 0.000 0.294 2.090 0.942 9.124
15 - 202245****** IQ7+M [5] VCOP 0.000 0.293 2.066 0.928 9.008
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 523.5 Ah (26.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.2 % State Of Health 100.0 %
Run Time 18d 4h 14m to empty Report Date 2021-05-11 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack