Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.650 kW
05/30/2026 14:58 (2194 days) Production Consumption NET Usage
Now 1.985 kW 0.335 kW -1.650 kW
Today 20.639 kWh (1.376 kW) 7.374 kWh (0.492 kW) -13.265 kWh (-0.884 kW)
  - This Week 179.254 kWh (27.060 kWh/day) 148.088 kWh (22.355 kWh/day) -31.166 kWh (-4.705 kWh/day)
  - This Month 741.249 kWh (25.022 kWh/day) 504.257 kWh (17.022 kWh/day) -236.992 kWh (-8.000 kWh/day)
  - This Year 2.694 MWh (18.007 kWh/day) 2.564 MWh (17.136 kWh/day) -0.130 MWh (-0.871 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 180.016 kWh (25.717 kWh/day) 151.890 kWh (21.699 kWh/day) -28.126 kWh (-4.018 kWh/day)
Last 30 Days (04/30/2026) 744.644 kWh (24.821 kWh/day) 508.114 kWh (16.937 kWh/day) -236.530 kWh (-7.884 kWh/day)
Last One Year 6.431 MWh (17.620 kWh/day) 7.837 MWh (21.470 kWh/day) 1.405 MWh (3.850 kWh/day)
Lifetime Since PTO 38.260 MWh (17.433 kW/day) 42.075 MWh (19.172 kW/day) 3.815 MWh (1.738 kW/day)
Lifetime Since Install 38.294 MWh 42.655 MWh 4.361 MWh
Voltage/Current 249.6 V / 8.0 A 249.6 V / 1.3 A 249.6 V / -6.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/15/2021 20:16 (14.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.199 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.523 1.893 11.191 0.000 kW
1.442 kWh
0.000 kW
8.649 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.442 1.806 10.686
03 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.460 1.826 10.865
04 - 202232****** IQ7+ [5] VCOP 0.000 0.302 1.497 1.866 11.026
05 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.276 1.645 9.836
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.452 1.817 10.741
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.309 1.661 9.877 0.000 kW
1.325 kWh
0.000 kW
6.626 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.313 1.711 9.962
09 - 202217****** IQ7+ [5] VCOP 0.000 0.300 1.331 1.691 9.998
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.339 1.736 10.158
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.334 1.744 10.156
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.280 1.743 1.967 11.753 0.000 kW
1.731 kWh
0.000 kW
6.923 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.282 1.708 1.888 11.455
14 - 202216****** IQ7+ [5] VCOP 0.000 0.283 1.746 1.964 11.745
15 - 202245****** IQ7+M [5] VCOP 0.000 0.279 1.726 1.938 11.592
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 520.8 Ah (26.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 86.8 % State Of Health 100.0 %
Run Time 18d 1h 59m to empty Report Date 2021-05-15 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.