Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.639 kW
07/17/2026 07:48 (2242 days) Production Consumption NET Usage
Now 0.984 kW 0.345 kW -0.639 kW
Today 2.467 kWh (0.316 kW) 3.652 kWh (0.468 kW) 1.185 kWh (0.152 kW)
  - This Week 148.494 kWh (27.886 kWh/day) 172.593 kWh (32.411 kWh/day) 24.099 kWh (4.526 kWh/day)
  - This Month 419.048 kWh (25.668 kWh/day) 570.556 kWh (34.948 kWh/day) 151.508 kWh (9.280 kWh/day)
  - This Year 4.029 MWh (20.417 kWh/day) 3.857 MWh (19.548 kWh/day) -0.172 MWh (-0.869 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 198.673 kWh (28.382 kWh/day) 237.550 kWh (33.936 kWh/day) 38.877 kWh (5.554 kWh/day)
Last 30 Days (06/17/2026) 742.726 kWh (24.758 kWh/day) 865.887 kWh (28.863 kWh/day) 123.161 kWh (4.105 kWh/day)
Last One Year 6.730 MWh (18.439 kWh/day) 7.644 MWh (20.944 kWh/day) 0.914 MWh (2.505 kWh/day)
Lifetime Since PTO 39.595 MWh (17.658 kW/day) 43.368 MWh (19.341 kW/day) 3.774 MWh (1.683 kW/day)
Lifetime Since Install 39.628 MWh 43.948 MWh 4.320 MWh
Voltage/Current 248.2 V / 4.0 A 248.2 V / 1.4 A 248.2 V / -2.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/07/2021 20:33 (14.4 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.634 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 2.022 1.940 10.274 0.000 kW
1.924 kWh
0.000 kW
11.542 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.926 1.856 9.837
03 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.933 1.871 9.957
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.960 1.884 10.015
05 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.756 1.698 9.124
06 - 202245****** IQ7+M [5] VCOP 0.000 0.287 1.945 1.875 9.948
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.291 1.770 1.735 9.059 0.000 kW
1.806 kWh
0.000 kW
9.030 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.803 1.724 9.198
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.798 1.742 9.170
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.828 1.743 9.312
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.831 1.740 9.257
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.258 2.038 1.916 10.370 0.000 kW
2.016 kWh
0.000 kW
8.062 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.258 1.979 1.881 10.148
14 - 202216****** IQ7+ [5] VCOP 0.000 0.258 2.037 1.919 10.432
15 - 202245****** IQ7+M [5] VCOP 0.000 0.260 2.009 1.889 10.260
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 525.9 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.7 % State Of Health 100.0 %
Run Time 18d 6h 14m to empty Report Date 2021-07-07 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.