Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.584 kW
05/30/2026 14:57 (2194 days) Production Consumption NET Usage
Now 1.930 kW 0.346 kW -1.584 kW
Today 20.588 kWh (1.375 kW) 7.365 kWh (0.492 kW) -13.223 kWh (-0.883 kW)
  - This Week 179.203 kWh (27.057 kWh/day) 148.079 kWh (22.358 kWh/day) -31.124 kWh (-4.699 kWh/day)
  - This Month 741.198 kWh (25.021 kWh/day) 504.248 kWh (17.022 kWh/day) -236.950 kWh (-7.999 kWh/day)
  - This Year 2.694 MWh (18.007 kWh/day) 2.564 MWh (17.136 kWh/day) -0.130 MWh (-0.871 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 179.970 kWh (25.710 kWh/day) 151.881 kWh (21.697 kWh/day) -28.089 kWh (-4.013 kWh/day)
Last 30 Days (04/30/2026) 744.618 kWh (24.821 kWh/day) 508.112 kWh (16.937 kWh/day) -236.506 kWh (-7.884 kWh/day)
Last One Year 6.431 MWh (17.620 kWh/day) 7.837 MWh (21.470 kWh/day) 1.405 MWh (3.850 kWh/day)
Lifetime Since PTO 38.260 MWh (17.433 kW/day) 42.075 MWh (19.172 kW/day) 3.815 MWh (1.738 kW/day)
Lifetime Since Install 38.294 MWh 42.655 MWh 4.361 MWh
Voltage/Current 249.8 V / 7.7 A 249.9 V / 1.4 A 249.8 V / -6.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/25/2021 20:25 (14.3 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.189 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.177 1.237 13.227 0.000 kW
2.154 kWh
0.000 kW
12.921 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.294 2.135 1.200 12.724
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.175 1.222 12.848
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.182 1.223 13.012
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.115 1.167 11.860
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 2.137 1.207 12.793
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 2.063 1.140 11.965 0.000 kW
2.110 kWh
0.000 kW
10.550 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.289 2.112 1.128 12.138
09 - 202217****** IQ7+ [5] VCOP 0.000 0.292 2.099 1.152 12.108
10 - 202244****** IQ7+M [5] VCOP 0.000 0.292 2.132 1.158 12.324
11 - 202224****** IQ7+M [5] VCOP 0.000 0.292 2.144 1.151 12.352
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.279 1.951 1.342 13.156 0.000 kW
1.930 kWh
0.000 kW
7.718 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.284 1.874 1.342 12.757
14 - 202216****** IQ7+ [5] VCOP 0.000 0.282 1.958 1.356 13.170
15 - 202245****** IQ7+M [5] VCOP 0.000 0.279 1.935 1.349 13.030
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.