Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.300 kW
04/09/2026 20:03 (2143 days) Production Consumption NET Usage
Now 0.317 kW -2.983 kW -3.300 kW
Today 37.635 kWh (1.876 kW) 9.131 kWh (0.455 kW) -28.504 kWh (-1.421 kW)
  - This Week 148.639 kWh (30.736 kWh/day) 65.763 kWh (13.599 kWh/day) -82.876 kWh (-17.138 kWh/day)
  - This Month 201.244 kWh (22.775 kWh/day) 126.822 kWh (14.353 kWh/day) -74.422 kWh (-8.423 kWh/day)
  - This Year 1.431 MWh (14.475 kWh/day) 1.692 MWh (17.121 kWh/day) 0.262 MWh (2.646 kWh/day)
Yesterday 39.481 kWh (1.645 kW) 21.070 kWh (0.878 kW) -18.411 kWh (-0.767 kW)
Last 7 Days 184.445 kWh (26.349 kWh/day) 98.513 kWh (14.073 kWh/day) -85.932 kWh (-12.276 kWh/day)
Last 30 Days (03/10/2026) 643.111 kWh (21.437 kWh/day) 445.585 kWh (14.853 kWh/day) -197.526 kWh (-6.584 kWh/day)
Last One Year 6.175 MWh (16.918 kWh/day) 7.830 MWh (21.451 kWh/day) 1.654 MWh (4.532 kWh/day)
Lifetime Since PTO 36.996 MWh (17.257 kW/day) 41.203 MWh (19.219 kW/day) 4.207 MWh (1.962 kW/day)
Lifetime Since Install 37.030 MWh 41.783 MWh 4.753 MWh
Voltage/Current 251.7 V / 1.3 A 251.6 V / -11.9 A 251.7 V / -13.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/11/2021 23:05 (11.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.350 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.105 0.304 1.422 12.809 0.000 kW
0.293 kWh
0.000 kW
1.759 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.102 0.287 1.398 12.561
03 - 202224****** IQ7+M [0] ---- 0.000 0.106 0.303 1.426 12.849
04 - 202232****** IQ7+ [0] ---- 0.000 0.105 0.299 1.426 12.860
05 - 202244****** IQ7+M [0] ---- 0.000 0.101 0.279 1.379 12.222
06 - 202245****** IQ7+M [0] ---- 0.000 0.102 0.288 1.388 12.249
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.093 0.269 1.444 12.866 0.000 kW
0.270 kWh
0.000 kW
1.351 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.093 0.267 1.431 12.727
09 - 202217****** IQ7+ [0] ---- 0.000 0.095 0.271 1.454 12.726
10 - 202244****** IQ7+M [0] ---- 0.000 0.095 0.274 1.462 13.155
11 - 202224****** IQ7+M [0] ---- 0.000 0.093 0.269 1.453 13.157
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.112 0.308 1.175 10.567 0.000 kW
0.310 kWh
0.000 kW
1.240 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.112 0.309 1.158 10.211
14 - 202216****** IQ7+ [0] ---- 0.000 0.111 0.314 1.191 10.605
15 - 202245****** IQ7+M [0] ---- 0.000 0.109 0.309 1.176 10.438
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.17 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 501.0 Ah (25.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 83.5 % State Of Health 100.0 %
Run Time 13d 22h 0m to empty Report Date 2021-04-11 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.