Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.911 kW
05/30/2026 14:56 (2194 days) Production Consumption NET Usage
Now 2.245 kW 0.334 kW -1.911 kW
Today 20.570 kWh (1.375 kW) 7.362 kWh (0.492 kW) -13.208 kWh (-0.883 kW)
  - This Week 179.185 kWh (27.056 kWh/day) 148.076 kWh (22.358 kWh/day) -31.109 kWh (-4.697 kWh/day)
  - This Month 741.180 kWh (25.021 kWh/day) 504.245 kWh (17.022 kWh/day) -236.935 kWh (-7.998 kWh/day)
  - This Year 2.694 MWh (18.007 kWh/day) 2.564 MWh (17.136 kWh/day) -0.130 MWh (-0.871 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 179.954 kWh (25.708 kWh/day) 151.879 kWh (21.697 kWh/day) -28.075 kWh (-4.011 kWh/day)
Last 30 Days (04/30/2026) 744.608 kWh (24.820 kWh/day) 508.112 kWh (16.937 kWh/day) -236.496 kWh (-7.883 kWh/day)
Last One Year 6.431 MWh (17.620 kWh/day) 7.837 MWh (21.470 kWh/day) 1.405 MWh (3.850 kWh/day)
Lifetime Since PTO 38.260 MWh (17.433 kW/day) 42.075 MWh (19.172 kW/day) 3.815 MWh (1.738 kW/day)
Lifetime Since Install 38.294 MWh 42.655 MWh 4.361 MWh
Voltage/Current 250.2 V / 9.0 A 250.0 V / 1.3 A 250.1 V / -7.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/06/2021 20:44 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.836 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.257 2.300 8.944 0.000 kW
2.149 kWh
0.000 kW
12.892 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.291 2.159 2.198 8.656
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.157 2.196 8.762
04 - 202232****** IQ7+ [5] VCOP 0.000 0.298 2.182 2.219 8.751
05 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.962 1.997 8.213
06 - 202245****** IQ7+M [5] VCOP 0.000 0.290 2.175 2.219 8.685
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 1.977 1.997 7.887 0.000 kW
2.029 kWh
0.000 kW
10.144 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.288 2.033 2.056 8.151
09 - 202217****** IQ7+ [5] VCOP 0.000 0.288 2.014 2.038 8.111
10 - 202244****** IQ7+M [5] VCOP 0.000 0.291 2.058 2.092 8.338
11 - 202224****** IQ7+M [5] VCOP 0.000 0.290 2.062 2.099 8.351
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.273 2.236 2.270 8.512 0.000 kW
2.200 kWh
0.000 kW
8.800 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.270 2.153 2.172 8.285
14 - 202216****** IQ7+ [5] VCOP 0.000 0.270 2.225 2.256 8.573
15 - 202245****** IQ7+M [5] VCOP 0.000 0.266 2.187 2.218 8.451
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 523.8 Ah (26.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.3 % State Of Health 100.0 %
Run Time 14d 13h 11m to empty Report Date 2021-06-06 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack