Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.703 kW
05/30/2026 14:02 (2194 days) Production Consumption NET Usage
Now 2.056 kW 0.353 kW -1.703 kW
Today 18.148 kWh (1.291 kW) 6.865 kWh (0.488 kW) -11.283 kWh (-0.803 kW)
  - This Week 176.763 kWh (26.843 kWh/day) 147.579 kWh (22.411 kWh/day) -29.184 kWh (-4.432 kWh/day)
  - This Month 738.758 kWh (24.971 kWh/day) 503.748 kWh (17.027 kWh/day) -235.010 kWh (-7.944 kWh/day)
  - This Year 2.692 MWh (17.995 kWh/day) 2.563 MWh (17.137 kWh/day) -0.128 MWh (-0.858 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 177.884 kWh (25.412 kWh/day) 151.393 kWh (21.628 kWh/day) -26.491 kWh (-3.784 kWh/day)
Last 30 Days (04/30/2026) 742.972 kWh (24.766 kWh/day) 508.136 kWh (16.938 kWh/day) -234.836 kWh (-7.828 kWh/day)
Last One Year 6.431 MWh (17.619 kWh/day) 7.836 MWh (21.470 kWh/day) 1.406 MWh (3.851 kWh/day)
Lifetime Since PTO 38.257 MWh (17.433 kW/day) 42.074 MWh (19.172 kW/day) 3.817 MWh (1.739 kW/day)
Lifetime Since Install 38.291 MWh 42.654 MWh 4.363 MWh
Voltage/Current 249.1 V / 8.3 A 249.0 V / 1.4 A 249.1 V / -6.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/12/2021 20:37 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.457 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.212 0.739 0.869 12.108 0.000 kW
0.724 kWh
0.000 kW
4.346 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.212 0.718 0.847 11.664
03 - 202224****** IQ7+M [5] VCOP 0.000 0.206 0.738 0.871 11.690
04 - 202232****** IQ7+ [5] VCOP 0.000 0.210 0.731 0.865 11.788
05 - 202244****** IQ7+M [5] VCOP 0.000 0.212 0.704 0.826 10.643
06 - 202245****** IQ7+M [5] VCOP 0.000 0.211 0.718 0.845 11.735
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.225 0.652 0.775 10.568 0.000 kW
0.670 kWh
0.000 kW
3.350 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.218 0.663 0.770 10.774
09 - 202217****** IQ7+ [5] VCOP 0.000 0.221 0.671 0.783 10.749
10 - 202244****** IQ7+M [5] VCOP 0.000 0.226 0.682 0.790 10.947
11 - 202224****** IQ7+M [5] VCOP 0.000 0.226 0.683 0.780 10.939
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.152 0.688 0.876 12.179 0.000 kW
0.690 kWh
0.000 kW
2.761 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.130 0.678 0.883 11.841
14 - 202216****** IQ7+ [5] VCOP 0.000 0.152 0.703 0.894 12.204
15 - 202245****** IQ7+M [5] VCOP 0.000 0.154 0.692 0.885 12.033
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.15 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 496.2 Ah (25.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 82.7 % State Of Health 100.0 %
Run Time 13d 18h 48m to empty Report Date 2021-06-12 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.