Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.422 kW
04/09/2026 18:52 (2143 days) Production Consumption NET Usage
Now 0.711 kW 0.289 kW -0.422 kW
Today 37.166 kWh (1.970 kW) 9.790 kWh (0.519 kW) -27.376 kWh (-1.451 kW)
  - This Week 148.170 kWh (30.957 kWh/day) 66.422 kWh (13.878 kWh/day) -81.748 kWh (-17.080 kWh/day)
  - This Month 200.775 kWh (22.851 kWh/day) 127.481 kWh (14.509 kWh/day) -73.294 kWh (-8.342 kWh/day)
  - This Year 1.430 MWh (14.478 kWh/day) 1.693 MWh (17.136 kWh/day) 0.263 MWh (2.659 kWh/day)
Yesterday 39.481 kWh (1.645 kW) 21.070 kWh (0.878 kW) -18.411 kWh (-0.767 kW)
Last 7 Days 183.977 kWh (26.282 kWh/day) 100.336 kWh (14.334 kWh/day) -83.641 kWh (-11.949 kWh/day)
Last 30 Days (03/10/2026) 642.642 kWh (21.421 kWh/day) 447.484 kWh (14.916 kWh/day) -195.158 kWh (-6.505 kWh/day)
Last One Year 6.175 MWh (16.917 kWh/day) 7.832 MWh (21.456 kWh/day) 1.657 MWh (4.539 kWh/day)
Lifetime Since PTO 36.996 MWh (17.257 kW/day) 41.204 MWh (19.220 kW/day) 4.208 MWh (1.963 kW/day)
Lifetime Since Install 37.030 MWh 41.784 MWh 4.754 MWh
Voltage/Current 251.1 V / 2.8 A 251.0 V / 1.2 A 251.0 V / -1.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/24/2021 23:41 (13.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 27.200 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.295 1.882 2.349 10.472 0.000 kW
1.821 kWh
0.000 kW
10.924 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.292 1.817 2.284 10.140
03 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.859 2.331 10.445
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.886 2.366 10.589
05 - 202244****** IQ7+M [5] VCOP 0.000 0.289 1.698 2.164 9.486
06 - 202245****** IQ7+M [5] VCOP 0.000 0.288 1.781 2.251 9.933
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.292 1.760 2.221 9.670 0.000 kW
1.753 kWh
0.000 kW
8.766 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.291 1.701 2.245 9.532
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 1.767 2.223 9.742
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.774 2.296 9.965
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.765 2.317 9.942
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.254 1.892 2.151 10.572 0.000 kW
1.878 kWh
0.000 kW
7.510 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.250 1.870 2.028 10.289
14 - 202216****** IQ7+ [5] VCOP 0.000 0.254 1.889 2.134 10.563
15 - 202245****** IQ7+M [5] VCOP 0.000 0.248 1.859 2.095 10.403
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 525.3 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.6 % State Of Health 100.0 %
Run Time 24d 7h 40m to empty Report Date 2021-04-24 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.