Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.081 kW
02/07/2026 18:49 (2082 days) Production Consumption NET Usage
Now 0.317 kW 0.398 kW 0.081 kW
Today 16.215 kWh (0.861 kW) 7.652 kWh (0.406 kW) -8.563 kWh (-0.455 kW)
  - This Week 110.196 kWh (16.240 kWh/day) 137.883 kWh (20.320 kWh/day) 27.687 kWh (4.080 kWh/day)
  - This Month 110.196 kWh (16.240 kWh/day) 137.883 kWh (20.320 kWh/day) 27.687 kWh (4.080 kWh/day)
  - This Year 0.356 MWh (9.412 kWh/day) 0.721 MWh (19.083 kWh/day) 0.365 MWh (9.672 kWh/day)
Yesterday 11.310 kWh (0.471 kW) 14.055 kWh (0.586 kW) 2.745 kWh (0.114 kW)
Last 7 Days 111.825 kWh (17.993 kWh/day) 141.329 kWh (22.740 kWh/day) 29.504 kWh (4.747 kWh/day)
Last 30 Days 273.253 kWh (9.353 kWh/day) 595.463 kWh (20.382 kWh/day) 322.210 kWh (11.029 kWh/day)
Last One Year 6.099 MWh (16.745 kWh/day) 7.567 MWh (20.777 kWh/day) 1.468 MWh (4.032 kWh/day)
Lifetime Since PTO 35.921 MWh (17.246 kW/day) 40.233 MWh (19.316 kW/day) 4.311 MWh (2.070 kW/day)
Lifetime Since Install 35.955 MWh 40.812 MWh 4.857 MWh
Voltage/Current 249.8 V / 1.3 A 249.7 V / 1.6 A 249.8 V / 0.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/25/2021 21:58 (10.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 20.806 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.284 1.542 1.586 1.911 0.000 kW
1.476 kWh
0.000 kW
8.856 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.276 1.442 1.542 1.801
03 - 202224****** IQ7+M [0] ---- 0.000 0.278 1.485 1.571 1.847
04 - 202232****** IQ7+ [0] ---- 0.000 0.280 1.465 1.560 1.865
05 - 202244****** IQ7+M [0] ---- 0.000 0.277 1.481 1.533 2.638
06 - 202245****** IQ7+M [0] ---- 0.000 0.277 1.441 1.540 2.641
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.302 1.590 1.788 4.508 0.000 kW
1.600 kWh
0.000 kW
8.002 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.300 1.405 1.689 3.591
09 - 202217****** IQ7+ [0] ---- 0.000 0.298 1.664 1.832 4.957
10 - 202244****** IQ7+M [0] ---- 0.000 0.303 1.674 1.866 5.272
11 - 202224****** IQ7+M [0] ---- 0.000 0.299 1.668 1.829 4.549
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.183 0.974 0.932 1.289 0.000 kW
0.987 kWh
0.000 kW
3.948 kWh
13 - 202223****** IQ7+ [0] V--- 0.000 0.182 0.981 0.957 1.227
14 - 202216****** IQ7+ [0] ---- 0.000 0.183 1.017 0.975 1.189
15 - 202245****** IQ7+M [0] ---- 0.000 0.179 0.976 0.958 1.277
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.