Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.851 kW
05/30/2026 11:44 (2194 days) Production Consumption NET Usage
Now 2.041 kW 0.190 kW -1.851 kW
Today 11.272 kWh (0.959 kW) 5.661 kWh (0.482 kW) -5.611 kWh (-0.477 kW)
  - This Week 169.887 kWh (26.180 kWh/day) 146.375 kWh (22.557 kWh/day) -23.512 kWh (-3.623 kWh/day)
  - This Month 731.882 kWh (24.819 kWh/day) 502.544 kWh (17.042 kWh/day) -229.338 kWh (-7.777 kWh/day)
  - This Year 2.685 MWh (17.961 kWh/day) 2.562 MWh (17.140 kWh/day) -0.123 MWh (-0.821 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 172.245 kWh (24.606 kWh/day) 151.782 kWh (21.683 kWh/day) -20.463 kWh (-2.923 kWh/day)
Last 30 Days (04/30/2026) 739.168 kWh (24.639 kWh/day) 507.864 kWh (16.929 kWh/day) -231.304 kWh (-7.710 kWh/day)
Last One Year 6.433 MWh (17.624 kWh/day) 7.836 MWh (21.469 kWh/day) 1.403 MWh (3.845 kWh/day)
Lifetime Since PTO 38.251 MWh (17.430 kW/day) 42.073 MWh (19.172 kW/day) 3.822 MWh (1.742 kW/day)
Lifetime Since Install 38.285 MWh 42.653 MWh 4.368 MWh
Voltage/Current 249.2 V / 8.2 A 249.1 V / 0.8 A 249.1 V / -7.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/18/2021 20:32 (14.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.829 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.157 2.447 10.422 0.000 kW
2.037 kWh
0.000 kW
12.224 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 2.043 2.321 9.916
03 - 202224****** IQ7+M [5] VCOP 0.000 0.300 2.043 2.320 9.956
04 - 202232****** IQ7+ [5] VCOP 0.000 0.300 2.073 2.344 10.028
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.835 2.104 9.066
06 - 202245****** IQ7+M [5] VCOP 0.000 0.298 2.074 2.355 10.057
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.883 2.071 8.874 0.000 kW
1.889 kWh
0.000 kW
9.444 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.882 2.173 9.213
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.891 2.121 9.130
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.894 2.189 9.353
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 1.894 2.208 9.379
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.274 2.308 2.483 10.541 0.000 kW
2.290 kWh
0.000 kW
9.161 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.272 2.277 2.364 10.169
14 - 202216****** IQ7+ [5] VCOP 0.000 0.274 2.308 2.465 10.554
15 - 202245****** IQ7+M [5] VCOP 0.000 0.270 2.267 2.415 10.374
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.95 V Current/Power -2.10 A (-0.113 kW)
Remain Capacity/Energy 539.1 Ah (27.6 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 89.9 % State Of Health 100.0 %
Run Time 10d 16h 42m to empty Report Date 2021-06-18 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.