Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.223 kW
12/17/2025 15:41 (2030 days) Production Consumption NET Usage
Now 0.142 kW 0.365 kW 0.223 kW
Today 6.964 kWh (0.444 kW) 7.111 kWh (0.453 kW) 0.147 kWh (0.009 kW)
  - This Week 25.967 kWh (7.104 kWh/day) 56.773 kWh (15.532 kWh/day) 30.806 kWh (8.428 kWh/day)
  - This Month 146.718 kWh (8.809 kWh/day) 318.046 kWh (19.097 kWh/day) 171.328 kWh (10.287 kWh/day)
  - This Year 6.016 MWh (17.156 kWh/day) 7.234 MWh (20.631 kWh/day) 1.219 MWh (3.475 kWh/day)
Yesterday 12.430 kWh (0.518 kW) 16.043 kWh (0.668 kW) 3.613 kWh (0.151 kW)
Last 7 Days 56.274 kWh (8.039 kWh/day) 143.442 kWh (20.492 kWh/day) 87.168 kWh (12.452 kWh/day)
Last 30 Days 261.914 kWh (8.730 kWh/day) 564.027 kWh (18.801 kWh/day) 302.113 kWh (10.070 kWh/day)
Last One Year 6.111 MWh (16.742 kWh/day) 7.577 MWh (20.760 kWh/day) 1.466 MWh (4.018 kWh/day)
Lifetime Since PTO 35.467 MWh (17.465 kW/day) 39.187 MWh (19.297 kW/day) 3.721 MWh (1.832 kW/day)
Lifetime Since Install 35.500 MWh 39.767 MWh 4.267 MWh
Voltage/Current 250.8 V / 0.6 A 250.7 V / 1.5 A 250.7 V / 0.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/06/2021 21:22 (9.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.880 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.235 0.977 0.334 2.656 0.000 kW
0.948 kWh
0.000 kW
5.687 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.211 0.914 0.302 2.424
03 - 202224****** IQ7+M [5] VCOP 0.000 0.209 0.916 0.316 2.487
04 - 202232****** IQ7+ [5] VCOP 0.000 0.209 0.891 0.318 2.439
05 - 202244****** IQ7+M [5] VCOP 0.000 0.227 0.989 0.301 2.517
06 - 202245****** IQ7+M [5] VC-- 0.000 0.231 1.001 0.317 2.651
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.278 1.288 0.329 2.989 0.000 kW
1.270 kWh
0.000 kW
6.348 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.275 1.132 0.323 2.655
09 - 202217****** IQ7+ [5] VCOP 0.000 0.279 1.333 0.333 3.139
10 - 202244****** IQ7+M [5] VCOP 0.000 0.280 1.328 0.337 3.140
11 - 202224****** IQ7+M [5] VCOP 0.000 0.277 1.267 0.331 2.954
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.120 0.418 0.288 1.851 0.000 kW
0.461 kWh
0.000 kW
1.845 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.133 0.481 0.290 1.919
14 - 202216****** IQ7+ [5] VCOP 0.000 0.134 0.478 0.294 1.937
15 - 202245****** IQ7+M [5] VCOP 0.000 0.130 0.469 0.289 1.892
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 54.55 V Current/Power 170.80 A (9.317 kW)
Remain Capacity/Energy 525.9 Ah (26.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 89.0 % State Of Health 98.5 %
Run Time 22m to full Report Date 2021-01-06 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 54.55 V Cell (MIN/MAX) 3.383 V / 3.426 V (0.043 V)
Current/Power 10.35 A (0.565 kW) Runtime 2h 5m to full
Remain Capacity/Energy 175.3 Ah (9.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 89.0 % State Of Health 98.5 %
Temperature 20.5 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-06 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.383 V 3.418 V 3.400 V 3.419 V 3.393 V 3.419 V 3.410 V 3.407 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.413 V 3.417 V 3.405 V 3.419 V 3.413 V 3.426 V 3.403 V 3.400 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -