Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.711 kW
04/09/2026 17:27 (2143 days) Production Consumption NET Usage
Now 2.074 kW 0.363 kW -1.711 kW
Today 35.072 kWh (2.008 kW) 8.798 kWh (0.504 kW) -26.274 kWh (-1.504 kW)
  - This Week 146.076 kWh (30.897 kWh/day) 65.430 kWh (13.839 kWh/day) -80.646 kWh (-17.058 kWh/day)
  - This Month 198.681 kWh (22.764 kWh/day) 126.489 kWh (14.493 kWh/day) -72.192 kWh (-8.271 kWh/day)
  - This Year 1.428 MWh (14.465 kWh/day) 1.692 MWh (17.136 kWh/day) 0.264 MWh (2.671 kWh/day)
Yesterday 39.481 kWh (1.645 kW) 21.070 kWh (0.878 kW) -18.411 kWh (-0.767 kW)
Last 7 Days 181.997 kWh (26.000 kWh/day) 100.301 kWh (14.329 kWh/day) -81.696 kWh (-11.671 kWh/day)
Last 30 Days (03/10/2026) 641.289 kWh (21.376 kWh/day) 447.978 kWh (14.933 kWh/day) -193.311 kWh (-6.444 kWh/day)
Last One Year 6.174 MWh (16.916 kWh/day) 7.831 MWh (21.456 kWh/day) 1.657 MWh (4.539 kWh/day)
Lifetime Since PTO 36.994 MWh (17.257 kW/day) 41.203 MWh (19.220 kW/day) 4.209 MWh (1.963 kW/day)
Lifetime Since Install 37.028 MWh 41.783 MWh 4.755 MWh
Voltage/Current 251.5 V / 8.2 A 251.5 V / 1.4 A 251.5 V / -6.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/17/2021 20:10 (14.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.121 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.082 1.495 12.228 0.000 kW
2.000 kWh
0.000 kW
12.003 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.299 2.005 1.427 11.689
03 - 202224****** IQ7+M [5] VCOP 0.000 0.299 2.015 1.446 11.841
04 - 202232****** IQ7+ [5] VCOP 0.000 0.298 2.052 1.467 12.034
05 - 202244****** IQ7+M [5] VCOP 0.000 0.301 1.835 1.282 10.700
06 - 202245****** IQ7+M [5] VCOP 0.000 0.299 2.013 1.434 11.754
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.903 1.310 10.794 0.000 kW
1.905 kWh
0.000 kW
9.523 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.889 1.290 10.900
09 - 202217****** IQ7+ [5] VCOP 0.000 0.299 1.910 1.317 10.923
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.914 1.331 11.087
11 - 202224****** IQ7+M [5] VCOP 0.000 0.299 1.908 1.325 11.099
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.287 2.171 1.542 12.822 0.000 kW
2.149 kWh
0.000 kW
8.595 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.287 2.106 1.540 12.496
14 - 202216****** IQ7+ [5] VCOP 0.000 0.287 2.172 1.555 12.816
15 - 202245****** IQ7+M [5] VCOP 0.000 0.284 2.145 1.540 12.656
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.20 A (-63 W)
Remain Capacity/Energy 520.8 Ah (26.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 86.8 % State Of Health 100.0 %
Run Time 18d 1h 59m to empty Report Date 2021-05-17 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.