Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.073 kW
11/01/2025 15:46 (1984 days) Production Consumption NET Usage
Now 1.626 kW 0.553 kW -1.073 kW
Today 15.838 kWh (1.002 kW) 7.787 kWh (0.493 kW) -8.051 kWh (-0.509 kW)
  - This Week 83.454 kWh (12.535 kWh/day) 60.138 kWh (9.033 kWh/day) -23.316 kWh (-3.502 kWh/day)
  - This Month 15.838 kWh (24.051 kWh/day) 7.787 kWh (11.825 kWh/day) -8.051 kWh (-12.226 kWh/day)
  - This Year 5.594 MWh (18.361 kWh/day) 6.340 MWh (20.810 kWh/day) 0.746 MWh (2.450 kWh/day)
Yesterday 11.508 kWh (0.480 kW) 14.230 kWh (0.593 kW) 2.722 kWh (0.113 kW)
Last 7 Days 79.908 kWh (11.415 kWh/day) 53.311 kWh (7.615 kWh/day) -26.597 kWh (-3.799 kWh/day)
Last 30 Days 453.805 kWh (15.127 kWh/day) 464.490 kWh (15.483 kWh/day) 10.685 kWh (0.356 kWh/day)
Last One Year 6.208 MWh (17.009 kWh/day) 7.407 MWh (20.292 kWh/day) 1.198 MWh (3.283 kWh/day)
Lifetime Since PTO 35.045 MWh (17.658 kW/day) 38.292 MWh (19.294 kW/day) 3.247 MWh (1.636 kW/day)
Lifetime Since Install 35.079 MWh 38.872 MWh 3.793 MWh
Voltage/Current 253.7 V / 6.4 A 253.8 V / 2.2 A 253.7 V / -4.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/11/2020 21:40 (8.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.585 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.185 0.738 0.764 3.718 0.000 kW
0.721 kWh
0.000 kW
4.328 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.183 0.709 0.742 3.615
03 - 202224****** IQ7+M [5] VCOP 0.000 0.186 0.692 0.726 3.595
04 - 202232****** IQ7+ [5] VCOP 0.000 0.182 0.657 0.681 3.425
05 - 202244****** IQ7+M [5] VCOP 0.000 0.186 0.756 0.809 3.862
06 - 202245****** IQ7+M [5] VCOP 0.000 0.184 0.777 0.821 3.849
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.237 0.914 0.999 4.613 0.000 kW
0.751 kWh
0.000 kW
3.755 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.000 3.119
09 - 202217****** IQ7+ [5] VCOP 0.000 0.240 0.981 1.097 4.937
10 - 202244****** IQ7+M [5] VCOP 0.000 0.240 0.971 1.077 4.895
11 - 202224****** IQ7+M [5] VCOP 0.000 0.238 0.888 0.980 4.637
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.092 0.348 0.313 1.934 0.000 kW
0.375 kWh
0.000 kW
1.502 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.093 0.390 0.360 2.116
14 - 202216****** IQ7+ [5] VCOP 0.000 0.093 0.389 0.358 2.118
15 - 202245****** IQ7+M [5] VCOP 0.000 0.090 0.375 0.347 2.062
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.29 V Current/Power 166.38 A (8.866 kW)
Remain Capacity/Energy 584.4 Ah (29.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.9 % State Of Health 98.5 %
Run Time 2m to full Report Date 2020-12-11 23:26
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.29 V Cell (MIN/MAX) 3.324 V / 3.335 V (0.011 V)
Current/Power -0.50 A (-26 W) Runtime 16d 2h 31m to empty
Remain Capacity/Energy 194.8 Ah (10.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 98.9 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-11 23:26
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.326 V 3.324 V 3.328 V 3.325 V 3.329 V 3.328 V 3.328 V 3.331 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.331 V 3.330 V 3.332 V 3.330 V 3.333 V 3.333 V 3.334 V 3.335 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -