Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.545 kW
05/30/2026 12:55 (2194 days) Production Consumption NET Usage
Now 4.023 kW 2.478 kW -1.545 kW
Today 14.901 kWh (1.151 kW) 6.270 kWh (0.484 kW) -8.631 kWh (-0.667 kW)
  - This Week 173.516 kWh (26.537 kWh/day) 146.984 kWh (22.479 kWh/day) -26.532 kWh (-4.058 kWh/day)
  - This Month 735.511 kWh (24.900 kWh/day) 503.153 kWh (17.034 kWh/day) -232.358 kWh (-7.866 kWh/day)
  - This Year 2.689 MWh (17.979 kWh/day) 2.563 MWh (17.138 kWh/day) -0.126 MWh (-0.840 kWh/day)
Yesterday 37.021 kWh (1.543 kW) 50.136 kWh (2.089 kW) 13.115 kWh (0.546 kW)
Last 7 Days 175.078 kWh (25.011 kWh/day) 151.027 kWh (21.575 kWh/day) -24.051 kWh (-3.436 kWh/day)
Last 30 Days (04/30/2026) 741.317 kWh (24.711 kWh/day) 508.044 kWh (16.935 kWh/day) -233.273 kWh (-7.776 kWh/day)
Last One Year 6.432 MWh (17.622 kWh/day) 7.836 MWh (21.470 kWh/day) 1.404 MWh (3.848 kWh/day)
Lifetime Since PTO 38.254 MWh (17.432 kW/day) 42.074 MWh (19.172 kW/day) 3.819 MWh (1.740 kW/day)
Lifetime Since Install 38.288 MWh 42.654 MWh 4.365 MWh
Voltage/Current 249.1 V / 16.2 A 249.1 V / 9.9 A 249.1 V / -6.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/12/2021 20:16 (13.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.464 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.065 0.871 10.239 0.000 kW
1.049 kWh
0.000 kW
6.291 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.039 0.846 9.852
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.063 0.874 10.005
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.058 0.871 10.047
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.028 0.844 9.271
06 - 202245****** IQ7+M [5] VCOP 0.000 0.301 1.039 0.849 9.918
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.005 0.839 9.232 0.000 kW
1.007 kWh
0.000 kW
5.037 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 0.999 0.837 9.301
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.009 0.846 9.341
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.014 0.852 9.436
11 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.010 0.850 9.424
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.292 1.030 0.770 10.032 0.000 kW
1.034 kWh
0.000 kW
4.135 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.297 1.029 0.752 9.807
14 - 202216****** IQ7+ [5] VCOP 0.000 0.296 1.045 0.787 10.039
15 - 202245****** IQ7+M [5] VCOP 0.000 0.293 1.031 0.775 9.970
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.