Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.256 kW
07/02/2025 06:35 (1862 days) Production Consumption NET Usage
Now 0.091 kW 0.347 kW 0.256 kW
Today 0.008 kWh (0.001 kW) 5.424 kWh (0.819 kW) 5.416 kWh (0.818 kW)
  - This Week 78.276 kWh (23.903 kWh/day) 104.469 kWh (31.902 kWh/day) 26.193 kWh (7.999 kWh/day)
  - This Month 20.990 kWh (16.457 kWh/day) 36.787 kWh (28.842 kWh/day) 15.797 kWh (12.385 kWh/day)
  - This Year 3.051 MWh (16.737 kWh/day) 3.164 MWh (17.359 kWh/day) 0.113 MWh (0.622 kWh/day)
Yesterday 20.982 kWh (0.875 kW) 31.363 kWh (1.307 kW) 10.381 kWh (0.433 kW)
Last 7 Days 152.396 kWh (21.775 kWh/day) 245.602 kWh (35.092 kWh/day) 93.206 kWh (13.317 kWh/day)
Last 30 Days 630.263 kWh (21.010 kWh/day) 789.503 kWh (26.318 kWh/day) 159.240 kWh (5.308 kWh/day)
Last One Year 6.340 MWh (17.370 kWh/day) 6.420 MWh (17.588 kWh/day) 0.079 MWh (0.218 kWh/day)
Lifetime Since PTO 32.502 MWh (17.453 kW/day) 35.116 MWh (18.857 kW/day) 2.614 MWh (1.404 kW/day)
Lifetime Since Install 32.535 MWh 35.696 MWh 3.160 MWh
Voltage/Current 249.1 V / 0.4 A 249.1 V / 1.4 A 249.1 V / 1.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/31/2020 23:38 (12.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.259 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.256 1.066 1.841 11.146 0.000 kW
1.048 kWh
0.000 kW
6.287 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.255 1.054 1.822 10.967
03 - 202224****** IQ7+M [5] VCOP 0.000 0.260 1.074 1.859 11.182
04 - 202232****** IQ7+ [5] VC-- 0.000 0.258 1.063 1.870 11.209
05 - 202244****** IQ7+M [5] VCOP 0.000 0.256 1.003 1.818 10.623
06 - 202245****** IQ7+M [5] VCOP 0.000 0.253 1.027 1.815 10.771
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.263 1.003 1.823 10.814 0.000 kW
1.005 kWh
0.000 kW
5.025 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.263 0.978 1.895 10.786
09 - 202217****** IQ7+ [5] VCOP 0.000 0.264 1.008 1.801 10.794
10 - 202244****** IQ7+M [5] VCOP 0.000 0.261 1.023 1.892 11.040
11 - 202224****** IQ7+M [5] VC-- 0.000 0.261 1.013 1.914 11.031
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.205 0.982 1.598 9.945 0.000 kW
0.987 kWh
0.000 kW
3.948 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.208 0.981 1.528 9.696
14 - 202216****** IQ7+ [5] VCOP 0.000 0.208 0.998 1.598 9.951
15 - 202245****** IQ7+M [5] VCOP 0.000 0.203 0.986 1.571 9.785
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 57.62 V Current/Power 179.90 A (10.365 kW)
Remain Capacity/Energy 589.8 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Run Time - to full Report Date 2020-09-01 00:00
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.62 V Cell (MIN/MAX) 3.584 V / 3.607 V (0.023 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 196.6 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-01 00:00
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.601 V 3.596 V 3.599 V 3.601 V 3.600 V 3.602 V 3.601 V 3.603 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.584 V 3.588 V 3.605 V 3.606 V 3.606 V 3.607 V 3.604 V 3.605 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -