Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.438 kW
09/13/2025 22:48 (1935 days) Production Consumption NET Usage
Now 0.000 kW 0.438 kW 0.438 kW
Today 22.447 kWh (0.984 kW) 23.511 kWh (1.031 kW) 1.064 kWh (0.047 kW)
  - This Week 148.841 kWh (21.414 kWh/day) 108.175 kWh (15.563 kWh/day) -40.666 kWh (-5.851 kWh/day)
  - This Month 285.769 kWh (22.067 kWh/day) 303.900 kWh (23.467 kWh/day) 18.131 kWh (1.400 kWh/day)
  - This Year 4.793 MWh (18.727 kWh/day) 5.475 MWh (21.389 kWh/day) 0.682 MWh (2.663 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.244 MWh (17.688 kW/day) 37.427 MWh (19.332 kW/day) 3.183 MWh (1.644 kW/day)
Lifetime Since Install 34.278 MWh 38.007 MWh 3.729 MWh
Voltage/Current 251.9 V / 0.0 A 251.9 V / 1.7 A 251.9 V / 1.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/17/2020 21:53 (9.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.735 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.147 0.397 1.152 4.074 0.000 kW
0.392 kWh
0.000 kW
2.350 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.146 0.392 1.133 4.086
03 - 202224****** IQ7+M [0] ---- 0.000 0.151 0.399 1.126 4.107
04 - 202232****** IQ7+ [0] ---- 0.000 0.145 0.388 1.082 3.983
05 - 202244****** IQ7+M [0] ---- 0.000 0.147 0.387 1.165 4.008
06 - 202245****** IQ7+M [0] ---- 0.000 0.146 0.389 1.136 3.860
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.168 0.388 1.351 4.587 0.000 kW
0.391 kWh
0.000 kW
1.957 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.168 0.385 1.196 4.055
09 - 202217****** IQ7+ [0] ---- 0.000 0.172 0.396 1.495 5.013
10 - 202244****** IQ7+M [0] ---- 0.000 0.169 0.398 1.475 4.970
11 - 202224****** IQ7+M [0] ---- 0.000 0.168 0.390 1.379 4.694
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.093 0.355 0.501 2.356 0.000 kW
0.357 kWh
0.000 kW
1.429 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.095 0.357 0.572 2.535
14 - 202216****** IQ7+ [0] ---- 0.000 0.095 0.363 0.564 2.459
15 - 202245****** IQ7+M [0] ---- 0.000 0.093 0.354 0.548 2.455
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.48 V Current/Power 163.88 A (8.600 kW)
Remain Capacity/Energy 352.8 Ah (18.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 59.7 % State Of Health 98.5 %
Run Time 1h 27m to full Report Date 2020-11-17 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.48 V Cell (MIN/MAX) 3.275 V / 3.284 V (0.009 V)
Current/Power -0.58 A (-30 W) Runtime 8d 9h 22m to empty
Remain Capacity/Energy 117.6 Ah (6.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 59.7 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-17 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.275 V 3.275 V 3.276 V 3.276 V 3.278 V 3.278 V 3.279 V 3.279 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.280 V 3.280 V 3.281 V 3.281 V 3.283 V 3.283 V 3.283 V 3.284 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -