Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.734 kW
07/01/2025 18:39 (1861 days) Production Consumption NET Usage
Now 0.020 kW 0.754 kW 0.734 kW
Today 20.981 kWh (1.123 kW) 25.499 kWh (1.365 kW) 4.518 kWh (0.242 kW)
  - This Week 78.267 kWh (28.176 kWh/day) 93.181 kWh (33.545 kWh/day) 14.914 kWh (5.369 kWh/day)
  - This Month 20.981 kWh (26.948 kWh/day) 25.499 kWh (32.750 kWh/day) 4.518 kWh (5.803 kWh/day)
  - This Year 3.051 MWh (16.782 kWh/day) 3.153 MWh (17.344 kWh/day) 0.102 MWh (0.561 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.502 MWh (17.457 kW/day) 35.105 MWh (18.855 kW/day) 2.603 MWh (1.398 kW/day)
Lifetime Since Install 32.535 MWh 35.685 MWh 3.149 MWh
Voltage/Current 250.0 V / 0.1 A 249.9 V / 3.0 A 250.0 V / 2.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/05/2020 23:30 (12.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 28.792 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.287 2.009 1.962 8.384 0.000 kW
1.979 kWh
0.000 kW
11.876 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.283 1.987 1.933 8.282
03 - 202224****** IQ7+M [5] VC-- 0.000 0.286 2.024 1.963 8.422
04 - 202232****** IQ7+ [5] VC-- 0.000 0.287 2.022 1.953 8.379
05 - 202244****** IQ7+M [5] VC-- 0.000 0.284 1.919 1.888 8.140
06 - 202245****** IQ7+M [5] VC-- 0.000 0.281 1.914 1.881 8.187
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 2.040 1.986 8.195 0.000 kW
2.042 kWh
0.000 kW
10.212 kWh
08 - 202245****** IQ7+M [5] VC-- 0.000 0.297 1.996 1.976 8.248
09 - 202217****** IQ7+ [5] VC-- 0.000 0.296 1.999 1.967 8.164
10 - 202244****** IQ7+M [5] VC-- 0.000 0.296 2.088 2.028 8.400
11 - 202224****** IQ7+M [5] VC-- 0.000 0.296 2.090 2.032 8.390
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.231 1.700 1.598 7.223 0.000 kW
1.676 kWh
0.000 kW
6.703 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.231 1.638 1.529 7.061
14 - 202216****** IQ7+ [5] VCOP 0.000 0.230 1.697 1.595 7.279
15 - 202245****** IQ7+M [5] VCOP 0.000 0.226 1.669 1.563 7.157
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 57.61 V Current/Power 180.03 A (10.372 kW)
Remain Capacity/Energy 586.2 Ah (30.0 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.2 % State Of Health 98.5 %
Run Time 1m to full Report Date 2020-09-05 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.