Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.516 kW
12/17/2025 14:39 (2030 days) Production Consumption NET Usage
Now 0.766 kW 0.250 kW -0.516 kW
Today 6.522 kWh (0.445 kW) 6.706 kWh (0.457 kW) 0.184 kWh (0.013 kW)
  - This Week 25.525 kWh (7.067 kWh/day) 56.368 kWh (15.606 kWh/day) 30.843 kWh (8.539 kWh/day)
  - This Month 146.276 kWh (8.806 kWh/day) 317.641 kWh (19.122 kWh/day) 171.365 kWh (10.316 kWh/day)
  - This Year 6.015 MWh (17.156 kWh/day) 7.234 MWh (20.632 kWh/day) 1.219 MWh (3.476 kWh/day)
Yesterday 12.430 kWh (0.518 kW) 16.043 kWh (0.668 kW) 3.613 kWh (0.151 kW)
Last 7 Days 56.274 kWh (8.039 kWh/day) 143.442 kWh (20.492 kWh/day) 87.168 kWh (12.452 kWh/day)
Last 30 Days 261.914 kWh (8.730 kWh/day) 564.027 kWh (18.801 kWh/day) 302.113 kWh (10.070 kWh/day)
Last One Year 6.111 MWh (16.742 kWh/day) 7.577 MWh (20.760 kWh/day) 1.466 MWh (4.018 kWh/day)
Lifetime Since PTO 35.466 MWh (17.465 kW/day) 39.187 MWh (19.298 kW/day) 3.721 MWh (1.832 kW/day)
Lifetime Since Install 35.500 MWh 39.767 MWh 4.267 MWh
Voltage/Current 251.5 V / 3.0 A 251.5 V / 1.0 A 251.5 V / -2.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/24/2021 21:53 (10.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.175 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.281 1.587 0.166 1.656 0.000 kW
1.556 kWh
0.000 kW
9.338 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.272 1.542 0.111 1.541
03 - 202224****** IQ7+M [5] VCOP 0.000 0.279 1.572 0.119 1.591
04 - 202232****** IQ7+ [5] VCOP 0.000 0.278 1.561 0.133 1.609
05 - 202244****** IQ7+M [5] VCOP 0.000 0.275 1.534 0.323 2.389
06 - 202245****** IQ7+M [5] VCOP 0.000 0.273 1.541 0.361 2.398
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 1.789 0.253 4.213 0.000 kW
1.802 kWh
0.000 kW
9.011 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.300 1.690 0.225 3.237
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 1.833 0.333 4.675
10 - 202244****** IQ7+M [4] VCOP 0.000 0.298 1.867 0.553 4.973
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 1.831 0.319 4.247
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.178 0.933 0.256 1.213 0.000 kW
0.957 kWh
0.000 kW
3.826 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.174 0.958 0.165 1.142
14 - 202216****** IQ7+ [5] VCOP 0.000 0.176 0.976 0.124 1.090
15 - 202245****** IQ7+M [5] VCOP 0.000 0.174 0.959 0.199 1.178
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.41 V Current/Power 0.00 A (0 W)
Remain Capacity/Energy 517.8 Ah (26.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 87.6 % State Of Health 98.5 %
Run Time Stand-by Report Date 2021-02-24 23:08
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack


Warning: unlink(images/chart_batt1_0.png): No such file or directory in C:\wamp64\www\solar\chart_batteries.php on line 185
JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.