Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.304 kW
07/01/2025 18:20 (1861 days) Production Consumption NET Usage
Now 0.072 kW 2.376 kW 2.304 kW
Today 20.970 kWh (1.142 kW) 25.022 kWh (1.362 kW) 4.052 kWh (0.221 kW)
  - This Week 78.256 kWh (28.306 kWh/day) 92.704 kWh (33.532 kWh/day) 14.448 kWh (5.226 kWh/day)
  - This Month 20.970 kWh (27.398 kWh/day) 25.022 kWh (32.692 kWh/day) 4.052 kWh (5.294 kWh/day)
  - This Year 3.051 MWh (16.784 kWh/day) 3.152 MWh (17.343 kWh/day) 0.102 MWh (0.559 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.502 MWh (17.457 kW/day) 35.104 MWh (18.855 kW/day) 2.603 MWh (1.398 kW/day)
Lifetime Since Install 32.535 MWh 35.684 MWh 3.149 MWh
Voltage/Current 248.4 V / 0.3 A 248.3 V / 9.6 A 248.4 V / 9.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/13/2020 23:06 (11.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.336 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.259 0.989 1.603 9.822 0.000 kW
0.972 kWh
0.000 kW
5.830 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.259 0.981 1.597 9.751
03 - 202224****** IQ7+M [5] VCOP 0.000 0.261 1.005 1.633 9.956
04 - 202232****** IQ7+ [5] VCOP 0.000 0.262 0.993 1.624 9.921
05 - 202244****** IQ7+M [5] VCOP 0.000 0.262 0.927 1.561 9.490
06 - 202245****** IQ7+M [5] VCOP 0.000 0.259 0.935 1.558 9.494
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.265 0.934 1.646 9.868 0.000 kW
0.928 kWh
0.000 kW
4.638 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.268 0.871 1.599 9.606
09 - 202217****** IQ7+ [5] VCOP 0.000 0.281 0.937 1.639 9.822
10 - 202244****** IQ7+M [5] VCOP 0.000 0.274 0.954 1.680 10.091
11 - 202224****** IQ7+M [5] VCOP 0.000 0.274 0.943 1.671 10.027
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.223 0.966 1.363 8.564 0.000 kW
0.967 kWh
0.000 kW
3.868 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.223 0.961 1.337 8.442
14 - 202216****** IQ7+ [5] VCOP 0.000 0.223 0.976 1.376 8.637
15 - 202245****** IQ7+M [5] VCOP 0.000 0.222 0.964 1.352 8.513
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 57.61 V Current/Power 179.84 A (10.360 kW)
Remain Capacity/Energy 580.5 Ah (29.7 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.2 % State Of Health 98.5 %
Run Time 3m to full Report Date 2020-09-13 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.61 V Cell (MIN/MAX) 3.587 V / 3.604 V (0.017 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 193.5 Ah (9.9 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 98.2 % State Of Health 98.5 %
Temperature 24.0 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-13 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.598 V 3.597 V 3.599 V 3.598 V 3.602 V 3.602 V 3.596 V 3.587 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.601 V 3.600 V 3.604 V 3.604 V 3.602 V 3.603 V 3.604 V 3.604 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -