Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.711 kW
10/31/2025 17:56 (1983 days) Production Consumption NET Usage
Now 0.000 kW 0.711 kW 0.711 kW
Today 11.508 kWh (0.641 kW) 7.589 kWh (0.423 kW) -3.919 kWh (-0.218 kW)
  - This Week 67.616 kWh (11.763 kWh/day) 45.710 kWh (7.952 kWh/day) -21.906 kWh (-3.811 kWh/day)
  - This Month 478.702 kWh (15.569 kWh/day) 470.650 kWh (15.307 kWh/day) -8.052 kWh (-0.262 kWh/day)
  - This Year 5.578 MWh (18.364 kWh/day) 6.326 MWh (20.825 kWh/day) 0.748 MWh (2.462 kWh/day)
Yesterday 1.140 kWh (0.047 kW) 14.195 kWh (0.591 kW) 13.055 kWh (0.544 kW)
Last 7 Days 83.693 kWh (11.956 kWh/day) 45.007 kWh (6.429 kWh/day) -38.686 kWh (-5.526 kWh/day)
Last 30 Days 467.194 kWh (15.573 kWh/day) 463.061 kWh (15.435 kWh/day) -4.133 kWh (-0.138 kWh/day)
Last One Year 6.212 MWh (17.019 kWh/day) 7.401 MWh (20.276 kWh/day) 1.189 MWh (3.257 kWh/day)
Lifetime Since PTO 35.029 MWh (17.658 kW/day) 38.278 MWh (19.296 kW/day) 3.249 MWh (1.638 kW/day)
Lifetime Since Install 35.063 MWh 38.858 MWh 3.795 MWh
Voltage/Current 253.6 V / 0.0 A 253.4 V / 2.8 A 253.5 V / 2.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/21/2021 22:17 (9.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.186 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.223 0.718 0.774 4.121 0.000 kW
0.688 kWh
0.000 kW
4.125 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.204 0.667 0.719 3.814
03 - 202224****** IQ7+M [5] VC-- 0.000 0.207 0.681 0.710 3.862
04 - 202232****** IQ7+ [5] VC-- 0.000 0.207 0.685 0.699 3.791
05 - 202244****** IQ7+M [5] VC-- 0.000 0.218 0.680 0.736 3.879
06 - 202245****** IQ7+M [5] ---- 0.000 0.217 0.694 0.759 4.013
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.277 0.871 0.911 4.397 0.000 kW
0.880 kWh
0.000 kW
4.401 kWh
08 - 202245****** IQ7+M [5] VC-- 0.000 0.276 0.857 0.781 3.865
09 - 202217****** IQ7+ [5] VCOP 0.000 0.279 0.895 0.932 4.733
10 - 202244****** IQ7+M [5] VCOP 0.000 0.281 0.895 0.929 4.707
11 - 202224****** IQ7+M [5] VCOP 0.000 0.280 0.883 0.888 4.343
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.139 0.405 0.425 2.717 0.000 kW
0.415 kWh
0.000 kW
1.660 kWh
13 - 202223****** IQ7+ [0] -C-- 0.000 0.140 0.420 0.453 2.785
14 - 202216****** IQ7+ [0] ---- 0.000 0.141 0.422 0.453 2.796
15 - 202245****** IQ7+M [5] ---- 0.000 0.138 0.413 0.442 2.722
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.