Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.682 kW
07/01/2025 12:46 (1861 days) Production Consumption NET Usage
Now 4.413 kW 2.731 kW -1.682 kW
Today 10.899 kWh (0.852 kW) 12.385 kWh (0.968 kW) 1.486 kWh (0.116 kW)
  - This Week 68.185 kWh (26.924 kWh/day) 80.067 kWh (31.616 kWh/day) 11.882 kWh (4.692 kWh/day)
  - This Month 10.899 kWh (20.440 kWh/day) 12.385 kWh (23.227 kWh/day) 1.486 kWh (2.787 kWh/day)
  - This Year 3.041 MWh (16.750 kWh/day) 3.140 MWh (17.295 kWh/day) 0.099 MWh (0.545 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.492 MWh (17.454 kW/day) 35.092 MWh (18.851 kW/day) 2.600 MWh (1.397 kW/day)
Lifetime Since Install 32.525 MWh 35.672 MWh 3.146 MWh
Voltage/Current 248.1 V / 17.8 A 248.1 V / 11.0 A 248.1 V / -6.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/22/2020 23:38 (11.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.522 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.272 1.799 1.826 11.251 0.000 kW
1.777 kWh
0.000 kW
10.663 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.268 1.783 1.813 11.156
03 - 202224****** IQ7+M [5] VCOP 0.000 0.271 1.808 1.842 11.332
04 - 202232****** IQ7+ [5] VCOP 0.000 0.269 1.793 1.832 11.268
05 - 202244****** IQ7+M [5] VCOP 0.000 0.271 1.748 1.776 10.948
06 - 202245****** IQ7+M [5] VCOP 0.000 0.267 1.733 1.762 10.915
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.894 1.921 11.592 0.000 kW
1.884 kWh
0.000 kW
9.419 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.779 1.799 11.081
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.910 1.927 11.647
10 - 202244****** IQ7+M [5] VCOP 0.000 0.294 1.924 1.945 11.764
11 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.913 1.934 11.692
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.197 1.376 1.408 9.037 0.000 kW
1.360 kWh
0.000 kW
5.439 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.197 1.336 1.376 8.866
14 - 202216****** IQ7+ [5] VCOP 0.000 0.196 1.376 1.416 9.093
15 - 202245****** IQ7+M [5] VCOP 0.000 0.193 1.350 1.392 8.951
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 56.03 V Current/Power 175.02 A (9.806 kW)
Remain Capacity/Energy 573.6 Ah (29.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 97.1 % State Of Health 98.5 %
Run Time 5m to full Report Date 2020-09-22 23:14
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.03 V Cell (MIN/MAX) 3.495 V / 3.508 V (0.013 V)
Current/Power -0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 191.2 Ah (9.8 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 97.1 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-22 23:14
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.500 V 3.497 V 3.499 V 3.501 V 3.499 V 3.501 V 3.503 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.501 V 3.501 V 3.501 V 3.500 V 3.504 V 3.504 V 3.508 V 3.505 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -