Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.055 kW
07/17/2026 05:31 (2242 days) Production Consumption NET Usage
Now 0.226 kW 0.281 kW 0.055 kW
Today 1.250 kWh (0.226 kW) 2.553 kWh (0.461 kW) 1.303 kWh (0.235 kW)
  - This Week 147.277 kWh (28.158 kWh/day) 171.494 kWh (32.788 kWh/day) 24.217 kWh (4.630 kWh/day)
  - This Month 417.831 kWh (25.743 kWh/day) 569.457 kWh (35.084 kWh/day) 151.626 kWh (9.342 kWh/day)
  - This Year 4.028 MWh (20.421 kWh/day) 3.856 MWh (19.552 kWh/day) -0.171 MWh (-0.869 kWh/day)
Yesterday 22.649 kWh (0.943 kW) 31.495 kWh (1.312 kW) 8.846 kWh (0.368 kW)
Last 7 Days 198.714 kWh (28.388 kWh/day) 237.851 kWh (33.979 kWh/day) 39.137 kWh (5.591 kWh/day)
Last 30 Days (06/17/2026) 742.394 kWh (24.746 kWh/day) 864.880 kWh (28.829 kWh/day) 122.486 kWh (4.083 kWh/day)
Last One Year 6.729 MWh (18.437 kWh/day) 7.646 MWh (20.949 kWh/day) 0.917 MWh (2.512 kWh/day)
Lifetime Since PTO 39.593 MWh (17.658 kW/day) 43.367 MWh (19.341 kW/day) 3.774 MWh (1.683 kW/day)
Lifetime Since Install 39.627 MWh 43.947 MWh 4.320 MWh
Voltage/Current 252.1 V / 0.9 A 252.0 V / 1.1 A 252.0 V / 0.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/23/2021 22:07 (9.9 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.061 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.133 0.430 0.988 8.333 0.000 kW
0.419 kWh
0.000 kW
2.514 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.129 0.409 0.937 7.900
03 - 202224****** IQ7+M [0] ---- 0.000 0.141 0.430 0.967 8.242
04 - 202232****** IQ7+ [0] ---- 0.000 0.134 0.426 0.927 8.016
05 - 202244****** IQ7+M [0] ---- 0.000 0.128 0.408 0.957 8.143
06 - 202245****** IQ7+M [0] ---- 0.000 0.126 0.411 0.930 7.981
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.145 0.418 0.960 9.038 0.000 kW
0.420 kWh
0.000 kW
2.098 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.165 0.415 0.819 8.130
09 - 202217****** IQ7+ [0] ---- 0.000 0.163 0.424 1.027 9.457
10 - 202244****** IQ7+M [0] ---- 0.000 0.155 0.423 0.999 9.370
11 - 202224****** IQ7+M [0] ---- 0.000 0.152 0.418 0.990 9.287
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.097 0.363 0.776 5.524 0.000 kW
0.362 kWh
0.000 kW
1.449 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.099 0.358 0.777 5.638
14 - 202216****** IQ7+ [0] ---- 0.000 0.100 0.365 0.784 5.725
15 - 202245****** IQ7+M [0] ---- 0.000 0.097 0.362 0.775 5.634
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.