Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.871 kW
07/01/2025 16:07 (1861 days) Production Consumption NET Usage
Now 0.904 kW 2.775 kW 1.871 kW
Today 20.200 kWh (1.250 kW) 19.409 kWh (1.201 kW) -0.791 kWh (-0.049 kW)
  - This Week 77.486 kWh (28.995 kWh/day) 87.091 kWh (32.590 kWh/day) 9.605 kWh (3.594 kWh/day)
  - This Month 20.200 kWh (30.010 kWh/day) 19.409 kWh (28.835 kWh/day) -0.791 kWh (-1.175 kWh/day)
  - This Year 3.050 MWh (16.788 kWh/day) 3.147 MWh (17.320 kWh/day) 0.097 MWh (0.532 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.501 MWh (17.458 kW/day) 35.099 MWh (18.853 kW/day) 2.598 MWh (1.395 kW/day)
Lifetime Since Install 32.535 MWh 35.679 MWh 3.144 MWh
Voltage/Current 245.6 V / 3.7 A 245.6 V / 11.3 A 245.6 V / 7.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/14/2020 22:29 (10.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.461 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.250 1.622 0.394 6.223 0.000 kW
1.594 kWh
0.000 kW
9.563 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.246 1.589 0.388 6.136
03 - 202224****** IQ7+M [5] VCOP 0.000 0.248 1.597 0.397 6.218
04 - 202232****** IQ7+ [5] VCOP 0.000 0.246 1.572 0.390 6.154
05 - 202244****** IQ7+M [5] VCOP 0.000 0.246 1.595 0.384 6.064
06 - 202245****** IQ7+M [5] VCOP 0.000 0.244 1.589 0.388 6.051
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.286 1.784 0.359 6.310 0.000 kW
1.794 kWh
0.000 kW
8.971 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.288 1.652 0.361 5.888
09 - 202217****** IQ7+ [5] VCOP 0.000 0.287 1.833 0.358 6.434
10 - 202244****** IQ7+M [5] VCOP 0.000 0.286 1.864 0.367 6.551
11 - 202224****** IQ7+M [5] VCOP 0.000 0.285 1.837 0.364 6.464
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.165 0.970 0.376 4.732 0.000 kW
0.982 kWh
0.000 kW
3.927 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.158 0.968 0.361 4.714
14 - 202216****** IQ7+ [5] VCOP 0.000 0.164 1.003 0.385 4.797
15 - 202245****** IQ7+M [5] VCOP 0.000 0.161 0.985 0.379 4.715
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.20 V Current/Power 166.16 A (8.840 kW)
Remain Capacity/Energy 510.9 Ah (26.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 86.4 % State Of Health 98.5 %
Run Time 28m to full Report Date 2020-10-14 23:17
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.20 V Cell (MIN/MAX) 3.319 V / 3.329 V (0.010 V)
Current/Power -0.50 A (-26 W) Runtime 14d 5h 17m to empty
Remain Capacity/Energy 170.3 Ah (8.7 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 86.4 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-10-14 23:17
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.319 V 3.321 V 3.321 V 3.322 V 3.322 V 3.323 V 3.324 V 3.324 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.325 V 3.326 V 3.326 V 3.327 V 3.327 V 3.328 V 3.328 V 3.329 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -