Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.348 kW
06/28/2026 00:00 (2223 days) Production Consumption NET Usage
Now 0.000 kW 0.348 kW 0.348 kW
Today 0.000 kWh 0.004 kWh 0.004 kWh
  - This Week 0.000 kWh 0.004 kWh 0.004 kWh
  - This Month 793.827 kWh (29.399 kWh/day) 642.700 kWh (23.802 kWh/day) -151.127 kWh (-5.597 kWh/day)
  - This Year 3.528 MWh (19.821 kWh/day) 3.213 MWh (18.049 kWh/day) -0.316 MWh (-1.773 kWh/day)
Yesterday 10.018 kWh (0.417 kW) 16.954 kWh (0.706 kW) 6.936 kWh (0.289 kW)
Last 7 Days 134.181 kWh (19.169 kWh/day) 155.828 kWh (22.261 kWh/day) 21.647 kWh (3.092 kWh/day)
Last 30 Days (05/29/2026) 891.563 kWh (29.719 kWh/day) 705.061 kWh (23.502 kWh/day) -186.502 kWh (-6.217 kWh/day)
Last One Year 6.692 MWh (18.334 kWh/day) 7.736 MWh (21.194 kWh/day) 1.044 MWh (2.860 kWh/day)
Lifetime Since PTO 39.094 MWh (17.586 kW/day) 42.723 MWh (19.219 kW/day) 3.629 MWh (1.633 kW/day)
Lifetime Since Install 39.128 MWh 43.303 MWh 4.176 MWh
Voltage/Current 252.2 V / 0.0 A 252.2 V / 1.4 A 252.2 V / 1.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/07/2026 23:46 (9.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 6.823 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.227 0.484 0.389 4.097 0.000 kW
0.476 kWh
0.000 kW
2.855 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.190 0.464 0.374 3.901
03 - 202224****** IQ7+M [0] ---- 0.000 0.196 0.485 0.392 4.173
04 - 202232****** IQ7+ [0] ---- 0.000 0.195 0.480 0.388 4.147
05 - 202244****** IQ7+M [0] ---- 0.000 0.217 0.466 0.375 3.844
06 - 202245****** IQ7+M [0] ---- 0.000 0.224 0.475 0.384 3.895
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.217 0.374 0.427 4.291 0.000 kW
0.479 kWh
0.000 kW
2.396 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.227 0.489 0.434 4.699
09 - 202217****** IQ7+ [0] ---- 0.000 0.255 0.542 0.431 5.062
10 - 202244****** IQ7+M [0] ---- 0.000 0.220 0.534 0.434 4.993
11 - 202224****** IQ7+M [0] ---- 0.000 0.249 0.457 0.430 4.713
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.138 0.325 0.272 2.059 0.000 kW
0.347 kWh
0.000 kW
1.387 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.144 0.342 0.288 2.262
14 - 202216****** IQ7+ [0] ---- 0.000 0.139 0.361 0.314 2.370
15 - 202245****** IQ7+M [0] ---- 0.000 0.138 0.359 0.310 2.367
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.062 kWh
0.000 kW
0.186 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.220 0.186 0.134 1.766
Panel Layout Each Group Production

Charger History
Voltage PV 0.63 V Voltage Charge 52.44 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 25.6 °C / 22.3 °C Flags 00/00/00 Energy Today 2.799 kWh @ 2026-01-07 23:58
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.63 V Current/Power -1.80 A (-94 W)
Remain Capacity/Energy 287.7 Ah (14.7 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 48.5 % State Of Health 98.9 %
Run Time 6d 15h 50m to empty Report Date 2026-01-07 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.