Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.528 kW
12/17/2025 09:57 (2030 days) Production Consumption NET Usage
Now 0.807 kW 0.279 kW -0.528 kW
Today 0.603 kWh (0.061 kW) 4.942 kWh (0.496 kW) 4.339 kWh (0.436 kW)
  - This Week 19.606 kWh (5.740 kWh/day) 54.604 kWh (15.985 kWh/day) 34.998 kWh (10.246 kWh/day)
  - This Month 140.357 kWh (8.550 kWh/day) 315.877 kWh (19.243 kWh/day) 175.520 kWh (10.693 kWh/day)
  - This Year 6.009 MWh (17.149 kWh/day) 7.232 MWh (20.639 kWh/day) 1.223 MWh (3.490 kWh/day)
Yesterday 12.430 kWh (0.518 kW) 16.043 kWh (0.668 kW) 3.613 kWh (0.151 kW)
Last 7 Days 56.274 kWh (8.039 kWh/day) 143.442 kWh (20.492 kWh/day) 87.168 kWh (12.452 kWh/day)
Last 30 Days 261.914 kWh (8.730 kWh/day) 564.027 kWh (18.801 kWh/day) 302.113 kWh (10.070 kWh/day)
Last One Year 6.111 MWh (16.742 kWh/day) 7.577 MWh (20.760 kWh/day) 1.466 MWh (4.018 kWh/day)
Lifetime Since PTO 35.460 MWh (17.464 kW/day) 39.185 MWh (19.299 kW/day) 3.725 MWh (1.834 kW/day)
Lifetime Since Install 35.494 MWh 39.765 MWh 4.271 MWh
Voltage/Current 250.5 V / 3.2 A 250.5 V / 1.1 A 250.5 V / -2.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/06/2021 22:33 (12.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.157 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.203 2.189 10.808 0.000 kW
2.158 kWh
0.000 kW
12.948 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.165 2.151 10.562
03 - 202224****** IQ7+M [5] VCOP 0.000 0.298 2.212 2.196 10.886
04 - 202232****** IQ7+ [5] VCOP 0.000 0.298 2.212 2.196 10.865
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.078 2.076 10.223
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 2.078 2.072 10.268
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 2.180 2.174 10.761 0.000 kW
2.186 kWh
0.000 kW
10.932 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 2.123 2.128 10.595
09 - 202217****** IQ7+ [5] VCOP 0.000 0.300 2.149 2.146 10.706
10 - 202244****** IQ7+M [5] VCOP 0.000 0.300 2.238 2.232 11.077
11 - 202224****** IQ7+M [5] VC-- 0.000 0.297 2.242 2.234 11.046
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.246 1.852 1.822 9.133 0.000 kW
1.819 kWh
0.000 kW
7.277 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.245 1.771 1.745 8.856
14 - 202216****** IQ7+ [5] VCOP 0.000 0.244 1.843 1.816 9.169
15 - 202245****** IQ7+M [5] VCOP 0.000 0.242 1.811 1.783 9.013
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 54.74 V Current/Power 0.00 A (0 W)
Remain Capacity/Energy 540.9 Ah (27.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 90.2 % State Of Health 100.0 %
Run Time Stand-by Report Date 2021-04-06 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.