Exporting to grid by 3.998 kW
04/09/2026 14:56 (2143 days) Production Consumption NET Usage
Now 4.240 kW 0.242 kW -3.998 kW
Today 26.488 kWh (1.773 kW) 7.620 kWh (0.510 kW) -18.868 kWh (-1.263 kW)
  - This Week 137.492 kWh (29.744 kWh/day) 64.252 kWh (13.900 kWh/day) -73.240 kWh (-15.844 kWh/day)
  - This Month 190.097 kWh (22.046 kWh/day) 125.311 kWh (14.533 kWh/day) -64.786 kWh (-7.513 kWh/day)
  - This Year 1.420 MWh (14.393 kWh/day) 1.691 MWh (17.143 kWh/day) 0.271 MWh (2.749 kWh/day)
Yesterday 39.481 kWh (1.645 kW) 21.070 kWh (0.878 kW) -18.411 kWh (-0.767 kW)
Last 7 Days 174.445 kWh (24.921 kWh/day) 101.322 kWh (14.475 kWh/day) -73.123 kWh (-10.446 kWh/day)
Last 30 Days (03/10/2026) 638.970 kWh (21.299 kWh/day) 448.140 kWh (14.938 kWh/day) -190.830 kWh (-6.361 kWh/day)
Last One Year 6.174 MWh (16.915 kWh/day) 7.832 MWh (21.458 kWh/day) 1.658 MWh (4.542 kWh/day)
Lifetime Since PTO 36.985 MWh (17.254 kW/day) 41.201 MWh (19.220 kW/day) 4.216 MWh (1.967 kW/day)
Lifetime Since Install 37.019 MWh 41.781 MWh 4.762 MWh
Voltage/Current 254.1 V / 16.7 A 253.9 V / 1.0 A 254.0 V / -15.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/30/2021 20:24 (14.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.791 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.300 2.177 0.765 10.758 0.000 kW
2.097 kWh
0.000 kW
12.582 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.085 0.730 10.340
03 - 202224****** IQ7+M [5] VCOP 0.000 0.298 2.114 0.753 10.523
04 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.138 0.755 10.597
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.970 0.691 9.731
06 - 202245****** IQ7+M [5] VCOP 0.000 0.299 2.098 0.733 10.381
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.967 0.664 9.719 0.000 kW
2.031 kWh
0.000 kW
10.155 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.300 2.046 0.654 9.806
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 2.001 0.672 9.795
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.063 0.676 9.946
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 2.079 0.671 9.946
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.290 2.051 0.809 10.668 0.000 kW
2.013 kWh
0.000 kW
8.053 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.289 1.949 0.813 10.425
14 - 202216****** IQ7+ [5] VCOP 0.000 0.288 2.044 0.825 10.706
15 - 202245****** IQ7+M [5] VCOP 0.000 0.289 2.009 0.816 10.582
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.22 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 531.9 Ah (27.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 88.7 % State Of Health 100.0 %
Run Time 14d 18h 36m to empty Report Date 2021-07-30 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.