Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.079 kW
07/01/2025 07:21 (1861 days) Production Consumption NET Usage
Now 0.312 kW 0.391 kW 0.079 kW
Today 0.101 kWh (0.014 kW) 5.653 kWh (0.766 kW) 5.552 kWh (0.752 kW)
  - This Week 57.387 kWh (24.878 kWh/day) 73.335 kWh (31.792 kWh/day) 15.948 kWh (6.914 kWh/day)
  - This Month 0.101 kWh (0.328 kWh/day) 5.653 kWh (18.384 kWh/day) 5.552 kWh (18.056 kWh/day)
  - This Year 3.030 MWh (16.711 kWh/day) 3.133 MWh (17.279 kWh/day) 0.103 MWh (0.569 kWh/day)
Yesterday 27.328 kWh (1.139 kW) 30.663 kWh (1.278 kW) 3.335 kWh (0.139 kW)
Last 7 Days 162.688 kWh (23.244 kWh/day) 259.372 kWh (37.058 kWh/day) 96.684 kWh (13.814 kWh/day)
Last 30 Days 628.575 kWh (20.953 kWh/day) 773.316 kWh (25.778 kWh/day) 144.741 kWh (4.825 kWh/day)
Last One Year 6.357 MWh (17.417 kWh/day) 6.402 MWh (17.539 kWh/day) 0.045 MWh (0.123 kWh/day)
Lifetime Since PTO 32.481 MWh (17.450 kW/day) 35.085 MWh (18.850 kW/day) 2.604 MWh (1.399 kW/day)
Lifetime Since Install 32.515 MWh 35.665 MWh 3.150 MWh
Voltage/Current 249.6 V / 1.3 A 249.4 V / 1.6 A 249.5 V / 0.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/21/2020 23:22 (10.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.718 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.220 0.610 0.591 7.629 0.000 kW
0.606 kWh
0.000 kW
3.637 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.219 0.603 0.583 7.488
03 - 202224****** IQ7+M [5] VCOP 0.000 0.226 0.613 0.593 7.568
04 - 202232****** IQ7+ [5] VCOP 0.000 0.223 0.606 0.584 7.488
05 - 202244****** IQ7+M [5] VCOP 0.000 0.222 0.601 0.588 7.541
06 - 202245****** IQ7+M [5] VCOP 0.000 0.220 0.602 0.588 7.537
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.273 0.621 0.699 8.325 0.000 kW
0.627 kWh
0.000 kW
3.134 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.274 0.622 0.691 7.711
09 - 202217****** IQ7+ [5] VCOP 0.000 0.271 0.628 0.712 8.598
10 - 202244****** IQ7+M [5] VCOP 0.000 0.273 0.635 0.719 8.695
11 - 202224****** IQ7+M [5] VCOP 0.000 0.271 0.628 0.713 8.551
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.154 0.481 0.374 4.923 0.000 kW
0.487 kWh
0.000 kW
1.948 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.159 0.486 0.382 5.003
14 - 202216****** IQ7+ [5] VCOP 0.000 0.160 0.495 0.392 5.093
15 - 202245****** IQ7+M [5] VCOP 0.000 0.150 0.486 0.383 5.004
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 56.02 V Current/Power 175.08 A (9.808 kW)
Remain Capacity/Energy 590.1 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Run Time - to full Report Date 2020-10-21 23:35
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.02 V Cell (MIN/MAX) 3.494 V / 3.504 V (0.010 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 196.7 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-10-21 23:35
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.494 V 3.500 V 3.496 V 3.500 V 3.500 V 3.503 V 3.501 V 3.502 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.501 V 3.503 V 3.500 V 3.504 V 3.503 V 3.501 V 3.503 V 3.503 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -