Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.162 kW
05/12/2026 23:57 (2176 days) Production Consumption NET Usage
Now 0.317 kW 0.155 kW -0.162 kW
Today 41.947 kWh (1.750 kW) 12.156 kWh (0.507 kW) -29.791 kWh (-1.243 kW)
  - This Week 81.792 kWh (27.274 kWh/day) 36.917 kWh (12.310 kWh/day) -44.875 kWh (-14.964 kWh/day)
  - This Month 299.867 kWh (24.992 kWh/day) 154.054 kWh (12.839 kWh/day) -145.813 kWh (-12.153 kWh/day)
  - This Year 2.253 MWh (17.068 kWh/day) 2.214 MWh (16.771 kWh/day) -0.039 MWh (-0.296 kWh/day)
Yesterday 19.729 kWh (0.821 kW) 10.766 kWh (0.448 kW) -8.963 kWh (-0.373 kW)
Last 7 Days 154.565 kWh (22.081 kWh/day) 110.466 kWh (15.781 kWh/day) -44.099 kWh (-6.300 kWh/day)
Last 30 Days (04/12/2026) 708.307 kWh (23.610 kWh/day) 437.710 kWh (14.590 kWh/day) -270.597 kWh (-9.020 kWh/day)
Last One Year 6.299 MWh (17.256 kWh/day) 7.791 MWh (21.346 kWh/day) 1.493 MWh (4.089 kWh/day)
Lifetime Since PTO 37.819 MWh (17.372 kW/day) 41.725 MWh (19.166 kW/day) 3.906 MWh (1.794 kW/day)
Lifetime Since Install 37.852 MWh 42.305 MWh 4.452 MWh
Voltage/Current 252.4 V / 1.3 A 252.5 V / 0.6 A 252.4 V / -0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/22/2025 23:48 (9.6 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.456 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.207 0.381 0.306 5.066 0.000 kW
0.373 kWh
0.000 kW
2.236 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.201 0.364 0.290 4.843
03 - 202224****** IQ7+M [0] ---- 0.000 0.207 0.378 0.305 5.050
04 - 202232****** IQ7+ [0] ---- 0.000 0.207 0.380 0.304 5.067
05 - 202244****** IQ7+M [0] ---- 0.000 0.200 0.362 0.284 4.863
06 - 202245****** IQ7+M [0] ---- 0.000 0.205 0.371 0.298 4.950
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.258 0.429 0.300 5.278 0.000 kW
0.432 kWh
0.000 kW
2.160 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.263 0.421 0.302 5.681
09 - 202217****** IQ7+ [0] ---- 0.000 0.264 0.430 0.303 5.899
10 - 202244****** IQ7+M [0] ---- 0.000 0.255 0.435 0.304 5.900
11 - 202224****** IQ7+M [0] ---- 0.000 0.263 0.446 0.303 5.780
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.109 0.241 0.251 2.655 0.000 kW
0.265 kWh
0.000 kW
1.061 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.104 0.255 0.266 2.991
14 - 202216****** IQ7+ [0] ---- 0.000 0.124 0.285 0.283 3.124
15 - 202245****** IQ7+M [0] ---- 0.000 0.131 0.280 0.283 3.088
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 14.828
Panel Layout Each Group Production

Charger History
Voltage PV 0.82 V Voltage Charge 52.34 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.8 °C / 24.6 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-11-22 23:56
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.56 V Current/Power -1.80 A (-94 W)
Remain Capacity/Energy 211.9 Ah (10.9 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 35.7 % State Of Health 98.9 %
Run Time 4d 21h 45m to empty Report Date 2025-11-22 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.