Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.366 kW
09/13/2025 17:54 (1935 days) Production Consumption NET Usage
Now 0.274 kW 2.640 kW 2.366 kW
Today 22.336 kWh (1.246 kW) 14.522 kWh (0.810 kW) -7.814 kWh (-0.436 kW)
  - This Week 148.730 kWh (22.045 kWh/day) 99.186 kWh (14.701 kWh/day) -49.544 kWh (-7.343 kWh/day)
  - This Month 285.658 kWh (22.411 kWh/day) 294.911 kWh (23.137 kWh/day) 9.253 kWh (0.726 kWh/day)
  - This Year 4.793 MWh (18.741 kWh/day) 5.466 MWh (21.371 kWh/day) 0.673 MWh (2.630 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.244 MWh (17.690 kW/day) 37.418 MWh (19.330 kW/day) 3.174 MWh (1.640 kW/day)
Lifetime Since Install 34.278 MWh 37.998 MWh 3.720 MWh
Voltage/Current 248.6 V / 1.1 A 248.6 V / 10.6 A 248.6 V / 9.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/12/2021 22:07 (9.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.814 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.237 0.996 0.389 5.161 0.000 kW
0.962 kWh
0.000 kW
5.774 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.230 0.938 0.354 4.788
03 - 202224****** IQ7+M [5] VCOP 0.000 0.234 0.933 0.377 4.815
04 - 202232****** IQ7+ [5] VCOP 0.000 0.234 0.901 0.382 4.658
05 - 202244****** IQ7+M [5] VCOP 0.000 0.230 0.996 0.346 5.133
06 - 202245****** IQ7+M [5] VCOP 0.000 0.230 1.009 0.365 5.249
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.289 1.242 0.376 6.250 0.000 kW
1.246 kWh
0.000 kW
6.228 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.288 1.092 0.369 5.454
09 - 202217****** IQ7+ [5] VCOP 0.000 0.293 1.332 0.383 6.703
10 - 202244****** IQ7+M [5] VCOP 0.000 0.288 1.329 0.386 6.644
11 - 202224****** IQ7+M [5] VCOP 0.000 0.290 1.233 0.375 6.174
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.092 0.415 0.336 2.659 0.000 kW
0.453 kWh
0.000 kW
1.812 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.107 0.474 0.339 2.917
14 - 202216****** IQ7+ [5] VCOP 0.000 0.109 0.469 0.345 2.915
15 - 202245****** IQ7+M [5] VCOP 0.000 0.105 0.455 0.337 2.840
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.74 V Current/Power 167.73 A (9.014 kW)
Remain Capacity/Energy 524.4 Ah (26.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 88.7 % State Of Health 98.5 %
Run Time 23m to full Report Date 2021-01-12 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.74 V Cell (MIN/MAX) 3.351 V / 3.366 V (0.015 V)
Current/Power -0.26 A (-13 W) Runtime 28d 8h 9m to empty
Remain Capacity/Energy 174.8 Ah (8.9 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 88.7 % State Of Health 98.5 %
Temperature 19.0 °C Cycle 30
MOSFET CFET = ON, DFET = ON Reported 2021-01-12 23:58
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.360 V 3.351 V 3.360 V 3.352 V 3.361 V 3.353 V 3.354 V 3.364 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.361 V 3.353 V 3.363 V 3.355 V 3.364 V 3.356 V 3.365 V 3.366 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -